Misclassification of Breast Imaging Reporting and Data System (BI‐RADS) Mammographic Density and Implications for Breast Density Reporting Legislation

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      eScholarship, University of California, 2015.
    • الموضوع:
      2015
    • نبذة مختصرة :
      USA states have begun legislating mammographic breast density reporting to women, requiring that women undergoing screening mammography who have dense breast tissue (Breast Imaging Reporting and Data System [BI-RADS] density c or d) receive written notification of their breast density; however, the impact that misclassification of breast density will have on this reporting remains unclear. The aim of this study was to assess reproducibility of the four-category BI-RADS density measure and examine its relationship with a continuous measure of percent density. We enrolled 19 radiologists, experienced in breast imaging, from a single integrated health care system. Radiologists interpreted 341 screening mammograms at two points in time 6 months apart. We assessed intra- and interobserver agreement in radiologists'; interpretations of BI-RADS density and explored whether agreement depended upon radiologist characteristics. We examined the relationship between BI-RADS density and percent density in a subset of 282 examinations. Intraradiologist agreement was moderate to substantial, with kappa varying across radiologists from 0.50 to 0.81 (mean = 0.69, 95% CI [0.63, 0.73]). Intraradiologist agreement was higher for radiologists with ≥10 years experience interpreting mammograms (difference in mean kappa = 0.10, 95% CI [0.01, 0.24]). Interradiologist agreement varied widely across radiologist pairs from slight to substantial, with kappa ranging from 0.02 to 0.72 (mean = 0.46, 95% CI [0.36, 0.55]). Of 145 examinations interpreted as "nondense" (BI-RADS density a or b) by the majority of radiologists, 82.8% were interpreted as "dense" (BI-RADS density c or d) by at least one radiologist. Of 187 examinations interpreted as "dense" by the majority of radiologists, 47.1% were interpreted as "nondense" by at least one radiologist. While the examinations of almost half of the women in our study were interpreted clinically as having BI-RADS density c or d, only about 10% of examinations had percent density >50%. Our results suggest that breast density reporting based on a single BI-RADS density interpretation may be misleading due to high interradiologist variability and a lack of correspondence between BI-RADS density and percent density.
    • File Description:
      application/pdf
    • الرقم المعرف:
      10.1111/tbj.12443
    • Rights:
      public
    • الرقم المعرف:
      edssch.oai:escholarship.org:ark:/13030/qt0fc366gt