نبذة مختصرة : Introduction: The development of costs-effective and sensitive screening solutions to prevent amblyopia and identify its risk factors (strabismus, refractive problems or mixed) is a significant priority of pediatric ophthalmology. The main objective of our study was to compare the classification performance of various vision screening tests, including classic, stereoacuity-based tests (Lang II, TNO, Stereo Fly, and Frisby), and non-stereoacuity-based, low-density static, dynamic, and noisy anaglyphic random dot stereograms. We determined whether the combination of non-stereoacuity-based tests integrated in the simplest artificial intelligence (AI) model could be an alternative method for vision screening. Methods: Our study, conducted in Spain and Hungary, is a non-experimental, cross-sectional diagnostic test assessment focused on pediatric eye conditions. Using convenience sampling, we enrolled 423 children aged 3.6–14 years, diagnosed with amblyopia, strabismus, or refractive errors, and compared them to age-matched emmetropic controls. Comprehensive pediatric ophthalmologic examinations ascertained diagnoses. Participants used filter glasses for stereovision tests and red-green goggles for an AI-based test over their prescribed glasses. Sensitivity, specificity, and the area under the ROC curve (AUC) were our metrics, with sensitivity being the primary endpoint. AUCs were analyzed using DeLong’s method, and binary classifications (pathologic vs. normal) were evaluated using McNemar’s matched pair and Fisher’s nonparametric tests. Results: Four non-overlapping groups were studied: (1) amblyopia (n = 46), (2) amblyogenic (n = 55), (3) non-amblyogenic (n = 128), and (4) emmetropic (n = 194), and a fifth group that was a combination of the amblyopia and amblyogenic groups. Based on AUCs, the AI combination of non-stereoacuity-based tests showed significantly better performance 0.908, 95% CI: (0.829–0.958) for detecting amblyopia and its risk factors than most classical tests: Lang II: 0.704, (0.648–0.755), ...
Relation: https://doi.org/10.3389/fmed.2023.1294559; info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/RYC-2016-20471; Csizek Z, Mikó-Baráth E, Budai A, Frigyik AB, Pusztai Á, Nemes VA, Závori L, Fülöp D, Czigler A, Szabó-Guth K, Buzás P, Piñero DP and Jandó G (2023) Artificial intelligence-based screening for amblyopia and its risk factors: comparison with four classic stereovision tests. Front. Med. 10:1294559. doi:10.3389/fmed.2023.1294559; http://hdl.handle.net/10045/139474
Rights: © 2023 Csizek, Mikó-Baráth, Budai, Frigyik, Pusztai, Nemes, Závori, Fülöp, Czigler, Szabó-Guth, Buzás, Piñero and Jandó. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. ; info:eu-repo/semantics/openAccess
No Comments.