Avaliação do nível de eficiência energética da envoltória de edifícios públicos educacionais da UFSM com base no RTQ-C ; Evaluation of energy efficiency level in educational buildings envelope of UFSM based in RTQ-C

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Santos, Joaquim Cesar Pizzutti dos; http://lattes.cnpq.br/6591314076760539; Cunha, Eduardo Grala da; Grigoletti, Giane de Campos
    • بيانات النشر:
      Universidade Federal de Santa Maria
      Brasil
      Engenharia Civil
      UFSM
      Programa de Pós-Graduação em Engenharia Civil
      Centro de Tecnologia
    • الموضوع:
      2013
    • Collection:
      Manancial - Repositório Digital da UFSM (Universidade Federal de Santa Maria)
    • نبذة مختصرة :
      In 2009, the Technical Regulations for Energy Efficiency Labelling of Commercial Buildings (RTQ-C) was published, which presents the methodology for evaluating the level of energy efficiency in buildings and it proposes limits of thermal transmittance and solar absorptance for opaque locks of walls and roofs. Thus, this work aimed, through the application of both methods of RTQ-C, to evaluate the energy efficiency level of educational buildings envelopment at the Federal University of Santa Maria, to compare the applicability and equivalence between existing methods and to assess the influence of different thermal transmittance and solar absorptance in locks evaluated by this. It was evaluated 19 buildings of classrooms and laboratories by the prescriptive method, while, by the simulation method, two buildings were evaluated with high charge density installed. For the buildings evaluated by both methods, the result of the equation of the prescriptive method corresponded to the result of the simulation. However, the attendance to the prerequisites of the envelope made all the buildings evaluated by the prescriptive method were decreased of levels A and B to the efficiency levels C and E. In addition, the replacement of thermal transmittance and solar absorptance parameters in locks of walls and roofs did not result in a lower efficiency level than B. Thus, it was observed that, for buildings with high power density installed of bioclimatic zone 2, the prerequisites of envelope did not shown in accordance with the energy consumption resulting from evaluations and, therefore, they should be reviewed. ; Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES ; Em 2009, foi lançado o Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais, de Serviço e Públicos (RTQ-C), que apresenta metodologias para avaliação do nível de eficiência energética nessas edificações e estipula limites de transmitância térmica e absortância solar para os fechamentos opacos de paredes e ...
    • File Description:
      application/pdf
    • Relation:
      http://repositorio.ufsm.br/handle/1/22845
    • الدخول الالكتروني :
      http://repositorio.ufsm.br/handle/1/22845
    • Rights:
      Attribution-NonCommercial-NoDerivatives 4.0 International ; http://creativecommons.org/licenses/by-nc-nd/4.0/
    • الرقم المعرف:
      edsbas.ECF7B9C9