Improving harmonization and standardization of expanded newborn screening results by optimization of the legacy flow injection analysis tandem mass spectrometry methods and application of a standardized calibration approach

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      American Association for Clinical Chemistry
    • الموضوع:
      2022
    • Collection:
      Cardiff University: ORCA (Online Research @ Cardiff)
    • نبذة مختصرة :
      BackgroundNewborn screening (NBS) laboratories in the United Kingdom adhere to common protocols based on single analyte cutoff values (COVs); therefore, interlaboratory harmonization is of paramount importance. Interlaboratory variation for screening analytes in UK NBS laboratories ranges from 17% to 59%. While using common stable isotope internal standards has been shown to significantly reduce interlaboratory variation, instrument set-up, sample extraction, and calibration approach are also key factors.MethodsDried blood spot (DBS) extraction processes, instrument set-up, mobile-phase composition, sample introduction technique, and calibration approach of flow injection analysis–tandem mass spectrometry (FIA-MS/MS) methods were optimized. Inter- and intralaboratory variation of methionine, leucine, phenylalanine, tyrosine, isovaleryl-carnitine, glutaryl-carnitine, octanoyl-carnitine, and decanoyl-carnitine were determined pre- and postoptimization, using 3 different calibration approaches.ResultsOptimal recovery of analytes from DBS was achieved with a 35-min extraction time and 80% methanol (150 μL). Optimized methodology decreased the mean intralaboratory percentage relative SD (%RSD) for the 8 analytes from 20.7% (range 4.1–46.0) to 5.4% (range 3.0–8.5). The alternative calibration approach reduced the mean interlaboratory %RSD for all analytes from 16.8% (range 4.1–25.0) to 7.1% (range 4.1–11.0). Nuclear magnetic resonance analysis of the calibration material highlighted the need for standardization. The purities of isovaleryl-carnitine and glutaryl-carnitine were 85.13% and 69.94% respectively, below the manufacturer’s stated values of ≥98%.ConclusionsFor NBS programs provided by multiple laboratories using single analyte COVs, harmonization and standardization of results can be achieved by optimizing legacy FIA-MS/MS methods, adopting a common analytical protocol, and using standardized calibration material rather than internal calibration.
    • File Description:
      application/pdf
    • Relation:
      https://orca.cardiff.ac.uk/id/eprint/153771/1/hvac070.pdf; Carling, Rachel S., Whyte, Emily, John, Catharine, Garstone, Rachelle, Goddard, Philippa, Greenfield, Toby, Hogg, Sarah L, Le Masurier, Clare, Cowen, Simon, Moat, Stuart J https://orca.cardiff.ac.uk/view/cardiffauthors/A0083848.html and Hopley, Christopher 2022. Improving harmonization and standardization of expanded newborn screening results by optimization of the legacy flow injection analysis tandem mass spectrometry methods and application of a standardized calibration approach. Clinical Chemistry 68 (8) , pp. 1075-1083. 10.1093/clinchem/hvac070 https://doi.org/10.1093/clinchem%2Fhvac070 file https://orca.cardiff.ac.uk/id/eprint/153771/1/hvac070.pdf
    • الرقم المعرف:
      10.1093/clinchem/hvac070
    • الدخول الالكتروني :
      https://orca.cardiff.ac.uk/id/eprint/153771/
      https://doi.org/10.1093/clinchem/hvac070
      https://orca.cardiff.ac.uk/id/eprint/153771/1/hvac070.pdf
    • Rights:
      cc_by_nc_nd_4_0
    • الرقم المعرف:
      edsbas.53305E60