Evaluation of data-driven respiratory gating waveforms for clinical PET imaging

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Springer
    • الموضوع:
      2019
    • Collection:
      Oxford University Research Archive (ORA)
    • نبذة مختصرة :
      Background We aimed to evaluate the clinical robustness of a commercially developed data-driven respiratory gating algorithm based on principal component analysis, for use in routine PET imaging. Methods One hundred fifty-seven adult FDG PET examinations comprising a total of 1149 acquired bed positions were used for the assessment. These data are representative of FDG scans currently performed at our institution. Data were acquired for 4 min/bed position (3 min/bed for legs). The data-driven gating (DDG) algorithm was applied to each bed position, including those where minimal respiratory motion was expected. The algorithm provided a signal-to-noise measure of respiratory-like frequencies within the data, denoted as R. Qualitative evaluation was performed by visual examination of the waveforms, with each waveform scored on a 3-point scale by two readers and then averaged (score S of 0 = no respiratory signal, 1 = some respiratory-like signal but indeterminate, 2 = acceptable signal considered to be respiratory). Images were reconstructed using quiescent period gating and compared with non-gated images reconstructed with a matched number of coincidences. If present, the SUVmax of a well-defined lesion in the thorax or abdomen was measured and compared between the two reconstructions. Results There was a strong (r = 0.86) and significant correlation between R and scores S. Eighty-six percent of waveforms with R ≥ 15 were scored as acceptable for respiratory gating. On average, there were 1.2 bed positions per patient examination with R ≥ 15. Waveforms with high R and S were found to originate from bed positions corresponding to the thorax and abdomen: 90% of waveforms with R ≥ 15 had bed centres in the range 5.6 cm superior to 27 cm inferior from the dome of the liver. For regions where respiratory motion was expected to be minimal, R tended to be ≺ 6 and S tended to be 0. The use of DDG significantly increased the SUVmax of focal lesions, by an average of 11% when considering lesions in bed positions with R ≥ ...
    • Relation:
      https://ora.ox.ac.uk/objects/uuid:db0b2d35-e87e-4f18-a006-7dcbfae44b7c; https://doi.org/10.1186/s13550-018-0470-9
    • الرقم المعرف:
      10.1186/s13550-018-0470-9
    • الدخول الالكتروني :
      https://doi.org/10.1186/s13550-018-0470-9
      https://ora.ox.ac.uk/objects/uuid:db0b2d35-e87e-4f18-a006-7dcbfae44b7c
    • Rights:
      info:eu-repo/semantics/openAccess ; CC Attribution (CC BY)
    • الرقم المعرف:
      edsbas.37371535