Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Efficacy of ultrasonography and mammography in detecting features of breast cancer

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Ovid Technologies (Wolters Kluwer Health), 2025.
    • الموضوع:
      2025
    • نبذة مختصرة :
      Introduction: Breast cancer (BC) is considered one of the most commonly diagnosed cancers. Early detection is critical for effective management. This study aims to assess the utility of ultrasonography (US) and mammography (MG) in detecting BC features. Methods: This retrospective cross-sectional study involved the electronic records of 263 female patients diagnosed with BC. The mean age was 45.71 ± 12.25 years (17–90 years). A cross-tabulation test was performed to correlate the presence of each malignant feature (Yes/No) on both US and MG and the final ultrasonography diagnosis (benign/malignant). The compatibility between the presence of each feature on both imaging techniques was measured by the percentage of agreement in reporting the feature that was reported as Kappa. The sensitivity and specificity for each feature were calculated, and the receiver operating characteristic curve was used to measure the area under the curve for each feature on both modalities. Results: The strong compatibility between the two techniques was 87.1%, 94.29%, 66.92%, 79.85%, 77.56%, 77.18, and 79.84% for irregular shape, uncircumscribed, spiculated margins, tissue distortion, nipple retraction, skin thickening, and the presence of lymphadenopathy, respectively (P < 0.001). Boxplots show that the sensitivity of the US ranged from 37% to 95%, and the specificity ranged from 27% to 91%. However, MG’s sensitivity ranged from 44% to 93%, and the specificity ranged from 36% to 73%. Conclusion: US and MG images show similar morphological changes, enhancing diagnostic accuracy in breast lesions. US characterizes echogenicity, provides real-time imaging, and uses color and pulsed Doppler techniques for vascularity and lymphadenopathy detection, while MG is better for identifying different calcification types.
    • ISSN:
      2278-7135
      2249-4863
    • الرقم المعرف:
      10.4103/jfmpc.jfmpc_1225_24
    • Rights:
      CC BY NC SA
      URL: http://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
    • الرقم المعرف:
      edsair.doi.dedup.....d82d4bdc339641047428b5a03746333b