نبذة مختصرة : To identify the efficacy of contrast-enhanced ultrasound (CEUS) in re-evaluating masses with inconsistent Breast Imaging Reporting and Data System (BI-RADS) on mammography (MG) and conventional ultrasound (US).A total of 637 breast lesions were evaluated with MG, US, and CEUS within 6 months and assessed as BI-RADS MG and US. CEUS was used as an additional screening to rerate BI-RADS US according to a five-point system. Lesions were divided into consistent or inconsistent group on the basis of BI-RADS MG and US assessment. The performance of MG, US, and CEUS in the overall and inconsistent group as well as the clinicopathological differences between consistent and inconsistent group were compared using Z test, Mann-Whitney U test, and t-test.The respective AUCs of MG and US were 0.742, 0.843 for overall group and 0.412, 0.789 for inconsistent group. The corresponding values of rerated CEUS BI-RADS were 0.958 and 0.950, which were significantly prior to those of MG and US (p