نبذة مختصرة : We reviewed the cases of 100 patients (mean age, 73 ± 10 yr; 64 men) who had mitral valve replacement with a Medtronic Mosaic porcine bioprosthesis from 1995 through 2011. The mean New York Heart Association (NYHA) class was 3 ± 0.7, and 52 patients were in atrial fibrillation. Prosthetic sizes were chiefly 27 mm (50 patients) and 29 mm (40 patients). Follow-up ended in December 2012 and is 97% complete, with a cumulative duration of 611 patient-years (mean duration, 6 ± 4.6 yr; maximum, 17.7 yr). The early mortality rate was 10% (6% in elective patients); late deaths occurred in 31 patients (5 valve-related). Actuarial survival rates at 5, 10, and 15 years were 74% ± 5%, 50% ± 6%, and 37% ± 8%. The mean NYHA class in survivors was 1.4 ± 0.6 (P 2; in 16 patients with 29-mm prostheses, the mean gradient was 4.5 ± 1.9 mmHg, and the effective orifice area, 1.63 ± 0.4 cm2. During nearly 17 years of follow-up, the Mosaic bioprosthesis has shown good overall clinical and hemodynamic performance after mitral valve replacement.