Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Adaptation of latex diagnosis parameters determination using multiplate reader and freeze-drying conservation to support large-scale utilization in rubber plantations

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Junaidi, Junaidi; Syafaah, Afdholiatus; Aji, Martini; Ismawanto, Sigit; Oktavia, Fetrina; Subandiyah, Siti; Montoro, Pascal; Nuringtyas, Tri Rini
  • المصدر:
    Trends in Sciences
  • نوع التسجيلة:
    Electronic Resource
  • الدخول الالكتروني :
    http://agritrop.cirad.fr/610365/
    http://agritrop.cirad.fr/610365/1/Junaidi_2024_Hevea_Latex_Diagnosis.pdf
    https://doi.org/10.48048/tis.2024.7963
    http://agritrop.cirad.fr/610365
    https://doi.org/10.48048/tis.2024.7963
    10.48048/tis.2024.7963
    info:eu-repo/semantics/altIdentifier/doi/10.48048/tis.2024.7963
    info:eu-repo/semantics/altIdentifier/purl/https://doi.org/10.48048/tis.2024.7963
    info:eu-repo/grantAgreement/////(FRA) Labex AGRO 2011-LBX-002
    info:eu-repo/grantAgreement/////(FRA) Rubber Redox
  • معلومة اضافية
    • Publisher Information:
      2024
    • نبذة مختصرة :
      The Latex Diagnosis (LD) is performed through the determination of dry rubber (DRC), sucrose (Suc), inorganic phosphorus (Pi) and thiol (RSH) contents. It is carried out through the colorimetric method using a single cuvette spectrophotometer, which is time-consuming and requires a high volume of chemicals. It also needs to be executed as soon as the samples are collected so that limits the adoption of LD. The adaptation of the protocol to a multiplate reader and suitable conservation aimed to overcome the limitations. The experiments were carried out at the Indonesian Rubber Research Institute, Sembawa, Palembang, and Research Center for Biotechnology, Universitas Gadjah Mada, Yogyakarta. Various combinations of solution volumes, adapted from standard protocol, were tested. The closest slope of the standard curve to control was then applied to 7 randomly selected trees. The result showed that for Suc, the composition of 10 µL samples, 30 µL of 2.5 % TCA and 210 µL anthrone reagent was suitable for determination using a multiplate reader. The combination of 40 µL of sample, 85 µL of 2.5 % TCA and 125 µL mL FeSO4 solution was suitable for Pi determination, while 100 µL samples, 5 µL DNTB and 100 µL Tris is recommended for RSH. The measurement using a multiplate reader resulted in comparable contents (average deviations were 1.83, 2.69 and 3.51 % for Suc, Pi, and RSH, respectively), lower time and chemicals consumptions, and a larger number of sample handling compared to single cuvette method. This study also tested the effect of freeze-drying for sample conservation. The result indicated that freeze-drying was able to maintain the Pi level (deviation 0.93 %). However, it increased Suc (deviation 19.43 %) and decreased ascorbate (AsA) significantly (deviation 43.60 %); therefore, freeze-drying might not be suitable for conserving serum samples in the LD method.
    • الموضوع:
    • Availability:
      Open access content. Open access content
      cc_by_nc
      info:eu-repo/semantics/openAccess
      https://creativecommons.org/licenses/by-nc/4.0
    • Note:
      text
      English
    • Other Numbers:
      FRCIR oai:agritrop.cirad.fr:610365
      Adaptation of latex diagnosis parameters determination using multiplate reader and freeze-drying conservation to support large-scale utilization in rubber plantations. Junaidi Junaidi, Syafaah Afdholiatus, Aji Martini, Ismawanto Sigit, Oktavia Fetrina, Subandiyah Siti, Montoro Pascal, Nuringtyas Tri Rini. 2024. Trends in Sciences, 21 (9):7963, 15 p.https://doi.org/10.48048/tis.2024.7963
      1457294679
    • Contributing Source:
      CIRAD
      From OAIster®, provided by the OCLC Cooperative.
    • الرقم المعرف:
      edsoai.on1457294679
HoldingsOnline