Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Towards harmonizing clinical linear energy transfer (LET) reporting in proton radiotherapy : A European multi-centric study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Publisher Information:
      Uppsala universitet, Medicinsk strålningsvetenskap Informa UK Limited 2022
    • نبذة مختصرة :
      Background Clinical data suggest that the relative biological effectiveness (RBE) in proton therapy (PT) varies with linear energy transfer (LET). However, LET calculations are neither standardized nor available in clinical routine. Here, the status of LET calculations among European PT institutions and their comparability are assessed. Materials and methods Eight European PT institutions used suitable treatment planning systems with their center-specific beam model to create treatment plans in a water phantom covering different field arrangements and fulfilling commonly agreed dose objectives. They employed their locally established LET simulation environments and procedures to determine the corresponding LET distributions. Dose distributions D1.1 and DRBE assuming constant and variable RBE, respectively, and LET were compared among the institutions. Inter-center variability was assessed based on dose- and LET-volume-histogram parameters. Results Treatment plans from six institutions fulfilled all clinical goals and were eligible for common analysis. D1.1 distributions in the target volume were comparable among PT institutions. However, corresponding LET values varied substantially between institutions for all field arrangements, primarily due to differences in LET averaging technique and considered secondary particle spectra. Consequently, DRBE using non-harmonized LET calculations increased inter-center dose variations substantially compared to D1.1 and significantly in mean dose to the target volume of perpendicular and opposing field arrangements (p < 0.05). Harmonizing LET reporting (dose-averaging, all protons, LET to water or to unit density tissue) reduced the inter-center variability in LET to the order of 10–15% within and outside the target volume for all beam arrangements. Consequentially, inter-institutional variability in DRBE decreased to that observed for D1.1. Conclusion Harmonizing the reported LET among PT centers is feasible and allows for co
    • الموضوع:
    • الرقم المعرف:
      10.1080.0284186X.2021.1992007
    • Note:
      application/pdf
      English
    • Other Numbers:
      UPE oai:DiVA.org:uu-455630
      0000-0002-2758-7222
      0000-0001-8171-2541
      0000-0003-4128-5498
      0000-0002-9450-6859
      doi:10.1080/0284186X.2021.1992007
      PMID 34686122
      ISI:000710086600001
      1348927304
    • Contributing Source:
      UPPSALA UNIV LIBR
      From OAIster®, provided by the OCLC Cooperative.
    • الرقم المعرف:
      edsoai.on1348927304
HoldingsOnline