Reliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo model

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Publisher Information:
      MDPI 2021-04-12
    • نبذة مختصرة :
      Resonance frequency analysis (RFA) is the most extended method for measuring implant stability. The implant stability quotient (ISQ) is the measure obtained by different RFA devices; however, inter- and intra-rater reliability and agreement of these instruments remain unknown. Thirty implants were placed in three different pig mandibles. ISQ was measured parallel and perpendicular (lingual) to the peg axis with Osstell® Beacon, Penguin® and MegaISQ® by two different investigators and furthermore, one performed a test-retest. Intraclass correlation coefficient was calculated to assess the intra- and inter-rater reliability. Pearson correlation coefficient was used to assess the agreement. Intraclass correlation coefficients ranged from 0.20 to 0.65 for the Osstell® Beacon; 0.57 to 0.86 for the Penguin®; and −0.01 to 0.60 for the MegaISQ®. The highest ISQ values were obtained using Penguin® (66.3) in a parallel measurement; the lowest, using the MegaISQ® (60.1) in a parallel measurement. The highest correlation values with the other devices were obtained by MegaISQ® in a parallel measurement. Osstell® Beacon and MegaISQ® showed lower reliability than Penguin®. Osstell® had good agreement for measuring ISQ both in parallel and perpendicular, and MegaISQ® had the best agreement for measuring ISQ in parallel
    • الموضوع:
    • Availability:
      Open access content. Open access content
      http://creativecommons.org/licenses/by-nc-nd/4.0
      info:eu-repo/semantics/openAccess
      Attribution-NonCommercial-NoDerivatives 4.0 Internacional
    • Note:
      English
    • Other Numbers:
      SUE oai:idus.us.es:11441/125619
      Blázquez-Hinarejos, M., Saka-Herrán, C., Díez-Alonso, V., Ayuso-Montero, R., Velasco-Ortega, E. y López-López, J. (2021). Reliability and agreement of three devices for measuring implant stability quotient in the animal ex vivo model. Applied Sciences, 11 (8)
      2076-3417
      10.3390/app11083453
      1333651471
    • Contributing Source:
      UNIV DE SEVILLA
      From OAIster®, provided by the OCLC Cooperative.
    • الرقم المعرف:
      edsoai.on1333651471
HoldingsOnline