Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Correlación de protoporfirina zinc y plomo en sangre en trabajadores de fábricas de baterías, de Bogotá, Colombia Correlation of zinc protoporphyrin with blood lead levels in car battery industry workers in Bogota, Colombia

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Instituto Nacional de Salud Pública, 2001.
    • الموضوع:
      2001
    • Collection:
      LCC:Public aspects of medicine
    • نبذة مختصرة :
      Objetivo. Determinar la utilidad de la protoporfirina zinc en sangre (PPz) como indicador de exposición a plomo en trabajadores de fábricas de baterías. Material y métodos. Se hizo un estudio transversal en 116 trabajadores de fábricas de baterías del sector informal en Bogotá, Colombia. La información sobre variables generales, ocupacionales y de salud fue obtenida por medio de una entrevista con los trabajadores. Se establecieron dos categorías para los valores de PPz: aquellos por debajo del valor límite de (70 µg/dl), y aquellos por arriba de este valor. Se empleó análisis de regresión lineal para medir la correlación entre los valores logarítmicos de PPz (>70 µg/dl) y plomo en sangre (PbS) (>38 µg/dl). Resultados. Se encontró un coeficiente de correlación semilogarítmica r=0.54, además de posibles asociaciones estadísticamente significativas entre los niveles elevados de PPz y el oficio actual de exposición directa (RM:3.35, IC 95% 1.02-11.91; p:0.02), emplear plomo como materia prima (RM:7.80, IC 95% 2.96-21.03; phttp://www.insp.mx/salud/index.htmlObjective. To determine the usefulness of zinc protoporphyrin in blood (PPz) as an indicator of lead exposure in workers of the homemade car battery industry. Material and methods. A cross-sectional study was performed in 116 workers of the car battery industry in Bogotá, Colombia. Data on general, occupational, and health variables were collected by interview. Two categories of PPz values were established: Those below the cutoff value (70 µg/dL) and those above it. A linear regression analysis was performed to measure the correlation between logarithm values of PPz (>70 µg/dL) and lead in blood (PbB) (>38 µg/dL). Results. A semi-logarithmic correlation coefficient of r=0.54 was found, and statistically significant associations between high levels of PPz and direct exposure to lead were observed (OR:3.35, 95% IC 1.02-11.91; p:0.02); for workers who often use lead as a raw material (OR:7.80, 95% IC 2.96-21.03; phttp://www.insp.mx/salud/index.html
    • File Description:
      electronic resource
    • ISSN:
      0036-3634
    • Relation:
      http://www.scielo.org.mx/scielo.php?script=sci_arttext&pid=S0036-36342001000300005; https://doaj.org/toc/0036-3634
    • الرقم المعرف:
      edsdoj.520e769e731c415081e7da9b0f366c8e