Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Evaluation of a Standardized Protocol for Thrombin Generation Assay

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Shire
  • المصدر:
    Calibrated Automated Thrombogram: A Scandinavian Multicenter Study
    Nair SC, Dargaud Y, Chitlur M, Srivastava A. Tests of global haemostasis and their applications in bleeding disorders. Haemophilia. 2010 Jul;16 Suppl 5:85-92. doi: 10.1111/j.1365-2516.2010.02304.x.
    Trossaert M, Regnault V, Sigaud M, Boisseau P, Fressinaud E, Lecompte T. Mild hemophilia A with factor VIII assay discrepancy: using thrombin generation assay to assess the bleeding phenotype. J Thromb Haemost. 2008 Mar;6(3):486-93. doi: 10.1111/j.1538-7836.2007.02861.x. Epub 2007 Nov 28.
    Dargaud Y, Trzeciak MC, Bordet JC, Ninet J, Negrier C. Use of calibrated automated thrombinography +/- thrombomodulin to recognise the prothrombotic phenotype. Thromb Haemost. 2006 Nov;96(5):562-7.
    Lecompte T, Wahl D, Perret-Guillaume C, Hemker HC, Lacolley P, Regnault V. Hypercoagulability resulting from opposite effects of lupus anticoagulants is associated strongly with thrombotic risk. Haematologica. 2007 May;92(5):714-5. doi: 10.3324/haematol.10577.
    Freyburger G, Macouillard G, Labrouche S, Sztark F. Coagulation parameters in patients receiving dabigatran etexilate or rivaroxaban: two observational studies in patients undergoing total hip or total knee replacement. Thromb Res. 2011 May;127(5):457-65. doi: 10.1016/j.thromres.2011.01.001. Epub 2011 Jan 31.
    Hacquard M, Perrin J, Lelievre N, Vigneron C, Lecompte T. Inter-individual variability of effect of 7 low molecular weight antithrombin-dependent anticoagulants studied in vitro with calibrated automated thrombography. Thromb Res. 2011 Jan;127(1):29-34. doi: 10.1016/j.thromres.2010.07.024. Epub 2010 Sep 17.
    Dargaud Y, Luddington R, Gray E, Lecompte T, Siegemund T, Baglin T, Hogwood J, Regnault V, Siegemund A, Negrier C. Standardisation of thrombin generation test--which reference plasma for TGT? An international multicentre study. Thromb Res. 2010 Apr;125(4):353-6. doi: 10.1016/j.thromres.2009.11.012. Epub 2009 Nov 26.
    Perrin J, Depasse F, Lecompte T; French-speaking CAT group and under the aegis of GEHT; French-speaking CAT group (all in France unless otherwise stated):; French-speaking CAT group all in France unless otherwise stated. Large external quality assessment survey on thrombin generation with CAT: further evidence for the usefulness of normalisation with an external reference plasma. Thromb Res. 2015 Jul;136(1):125-30. doi: 10.1016/j.thromres.2014.12.015. Epub 2014 Dec 24.
    Hemker HC, Giesen P, Al Dieri R, Regnault V, de Smedt E, Wagenvoord R, Lecompte T, Beguin S. Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb. 2003;33(1):4-15. doi: 10.1159/000071636.