      Aim: The objective of the current study is to determine the concentration of aflatoxin B1 using high-performance liquid chromatography (HPLC) with a photodiode array (PDA) detector. Materials and methods: Aflatoxin B1 certified reference grade from Trilogy Analytical Laboratory dissolved acetonitrile (ACN) at 10 µg/mL was using standard assessment. HPLC instruments such as ultraviolet-PDA detector used a Shimadzu LC-6AD pump with DGU-20A5 degasser, communication module-20A, and PDA detector SPD-M20A with FRC-10A fraction collector. The HPLC was set isocratic method at 354 nm with a reverse-phase ODS C18 column (LiChrospher® 100 RP-18; diameter, 5 µm) under a 20°C controlled column chamber. Rheodyne® sample loops were performed in 20 µL capacities. The mobile phase was performed at fraction 63:26:11 H2O: methanol:ACN at pH 6.8. A total of 1 kg of feed contained 10% bread crumbs and 30% concentrated, 40% forage, and 20% soybean dregs were using commercials samples. Samples were extracted by ACN and separated with solid phase extraction ODS 1 mL than elution with mobile phase to collect at drying samples performed. The samples were ready to use after added 1 mL mobile phase than injected into the system of HPLC. Results: We found that the retention time of aflatoxin B1 was approximately 10.858 min. Linearity of 0.01-0.08 µg/mL aflatoxin B1 dissolved in mobile phase was obtained at R2=0.9. These results demonstrate that these methods can be used to analyze aflatoxin B1 and gain 89-99% recovery. The limit of detection of this assay was obtained at 3.5 × 10-6 µg/mL. Conclusion: This method was easy to apply and suitable to analyzing at small concentrations of aflatoxin B1 in formulated product of feed cattle. Keywords: feeds supplements; high-performance liquid chromatography photodiode array detector; isocratic methods; mycotoxin
    • File Description:
      text
    • Relation:
      http://repository.unair.ac.id/103853/1/Bukti%20C%2001%20High-performance%20liquid.pdf; http://repository.unair.ac.id/103853/2/Bukti%20C%2001%20High-Performance%20Liquid.pdf; http://repository.unair.ac.id/103853/3/Turnitin%20C%2001%20-%20High-performance%20liquid%20chromatography.pdf; http://repository.unair.ac.id/103853/7/High-performance%20liquid%20chromatography%20ultraviolet-photodiode%20array.pdf; Mochammad Lazuardi, - and Bambang Hermanto, - (2017) High-performance liquid chromatography ultraviolet-photodiode array detection method for aflatoxin B1 in cattle feed supplements. Veterinary World, 10 (8). pp. 3-9. ISSN 0972-8988, EISSN 2231-0916
    • الدخول الالكتروني :
      http://repository.unair.ac.id/103853/
      http://repository.unair.ac.id/103853/1/Bukti%20C%2001%20High-performance%20liquid.pdf
      http://repository.unair.ac.id/103853/2/Bukti%20C%2001%20High-Performance%20Liquid.pdf
      http://repository.unair.ac.id/103853/3/Turnitin%20C%2001%20-%20High-performance%20liquid%20chromatography.pdf
      http://repository.unair.ac.id/103853/7/High-performance%20liquid%20chromatography%20ultraviolet-photodiode%20array.pdf
      https://www.veterinaryworld.org/
    • الرقم المعرف:
      edsbas.FF2CFD23