Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      IOP
    • الموضوع:
      2016
    • Collection:
      Institutional Repository of Leibniz Universität Hannover
    • نبذة مختصرة :
      Due to its high sensitivity, compact size and low cost Ion Mobility Spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R = 90. In this study, we evaluated the performance of this GC-IMS under clinical conditions in a COPD study to find correlations between VOCs (10 ppbv to 1 ppmv) and COPD. Furthermore, in order to investigate possible correlations between ultra-low concentrated breath VOCs (0.1 pptv to 1 ppbv) and COPD, a modified mass spectrometer (MS) with atmospheric pressure chemical ionization (APCI) and GC pre-separation (GC-APCI-MS) was used. The GC-IMS has been used in 58 subjects (21 smokers with moderate COPD, 12 ex-smokers with COPD, 16 healthy smokers and 9 non-smokers). GC-APCI-MS data were available for 94 subjects (21 smokers with moderate COPD, 25 ex-smokers with COPD, 25 healthy smokers and 23 non-smokers). For 44 subjects, a comparison between GC-IMS and GC-APCI-MS data could be performed. Due to service intervals, subject availability and corrupt data, patient numbers were different for GC-APCI-MS and GC-IMS measurements. Using GC-IMS, three VOCs have been found showing a significant difference between healthy controls and patients with COPD. In the GC-APCI-MS data, we only observed one distinctive VOC, which has been identified as 2-pentanone. This proof-of-principle study shows the potential of our high-resolution GC-IMS in the clinical environment. Due to different linear dynamic response ranges, the data of GC-IMS and GC-APCI-MS were only comparable to a limited extent.
    • ISSN:
      1752-7155
    • Relation:
      ESSN:1752-7163; http://dx.doi.org/10.15488/10987; https://www.repo.uni-hannover.de/handle/123456789/11069
    • الرقم المعرف:
      10.15488/10987
    • Rights:
      Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. ; frei zugänglich
    • الرقم المعرف:
      edsbas.F52A037