Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Potential sources of quantification error when retrospectively assessing metacarpal bone loss from historical radiographs by using digital X-ray radiogrammetry : an experimental study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV
      Linköpings universitet, Avdelningen för radiologiska vetenskaper
      Linköpings universitet, Hälsouniversitetet
      Östergötlands Läns Landsting, Röntgenkliniken i Linköping
      Sectra Imtec AB, Linköping, Sweden
      Karolinska Institutet, Karolinska University Hospital, Stockholm, Sweden
    • الموضوع:
      2014
    • Collection:
      Linköping University Electronic Press (LiU E-Press)
    • نبذة مختصرة :
      During the past 15 yr, digital X-ray radiogrammetry (DXR) has been used to measure metacarpal bone mineral density (BMD). BMD is often measured in existing cohorts where X-ray images were not acquired in accordance with the DXR imaging protocol (DIP). The purpose of the present study was to analyze how deviations from DIP in historical radiographs may affect the reproducibility of DXR-BMD measurements. Cadaver hand phantoms were used to conduct repeat measurements of deviations from DIP with respect to voltage, exposure, lateral displacement, supination, combination of lateral displacement and supination or rotation, extension of the wrist, and edge enhancement. Direct digital radiography (Aristos; Siemens Healthcare, Erlangen, Germany) was used for image acquisition and dxr-online (Sectra, Linkoping, Sweden) for DXR-BMD measurements. The influence of the tested deviations from DIP ranged from 0 to 32.5 mg/cm(2) (0-6.8%). On repetition with the same specimen, none of the deviations resulted in a within-specimen reproducibility error greater than 2 mg/cm(2) (0.4%, equivalent to a T-score of 0.042). Among the tested deviations, all except tube voltage had a magnitude greater than the normal measurement noise for the technique and must therefore be considered when planning a study based on historical images.
    • File Description:
      application/pdf
    • ISBN:
      978-0-00-331598-1
      0-00-331598-3
    • Relation:
      Journal of clinical densitometry, 1094-6950, 2014, 17:1, s. 104-108; http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-105587; PMID 23664111; ISI:000331598300018
    • الرقم المعرف:
      10.1016/j.jocd.2013.04.002
    • الدخول الالكتروني :
      http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-105587
      https://doi.org/10.1016/j.jocd.2013.04.002
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.E9B3E9EF