Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Sorption Efficiency of a New Sorbent towards Cadmium(II): Methylphosphonic Acid Grafted Polystyrene Resin

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Université de Tlemcen; Laboratoire de chimie moléculaire et thioorganique (LCMT); Université de Caen Normandie (UNICAEN); Normandie Université (NU)-Normandie Université (NU)-École Nationale Supérieure d'Ingénieurs de Caen (ENSICAEN); Normandie Université (NU)-Institut Normand de Chimie Moléculaire Médicinale et Macromoléculaire (INC3M); Normandie Université (NU)-Université Le Havre Normandie (ULH); Normandie Université (NU)-Université de Rouen Normandie (UNIROUEN); Normandie Université (NU)-Institut national des sciences appliquées Rouen Normandie (INSA Rouen Normandie); Institut National des Sciences Appliquées (INSA)-Normandie Université (NU)-Institut National des Sciences Appliquées (INSA)-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Université Le Havre Normandie (ULH); Institut National des Sciences Appliquées (INSA)-Normandie Université (NU)-Institut National des Sciences Appliquées (INSA)-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Centre National de la Recherche Scientifique (CNRS)
    • بيانات النشر:
      HAL CCSD
      Hindawi Publishing Corporation
    • الموضوع:
      2013
    • Collection:
      Normandie Université: HAL
    • نبذة مختصرة :
      International audience ; A new chelating polymeric sorbent has been developed using polystyrene resin grafted with phosphonic acid. After characterization by FTIR and elementary analysis, the new resin has been investigated in liquid-solid extraction of cadmium(II). The results indicated that phosphonic resin could adsorb Cd(II) ion effectively from aqueous solution. The adsorption was strongly dependent on the pH of the medium and the optimum pH value level for better sorption was between 3.2 and 5.2. The influence of other analytical parameters including contact time, amount of resin, metal ion concentration, and the presence of some electrolytes was investigated. The maximum uptake capacity of Cd(II) ions was 37,9 mg·g−1 grafted resin at ambient temperature, at an initial pH value of 5.0. The overall adsorption process was best described by pseudo second-order kinetic. When Freundlich and Langmuir isotherms were tested, the latter had a better fit with the experimental data. Furthermore, more than 92% of Cd(II) could be eluted by using 1.0 mol·L−1 HCl in one cycle.
    • Relation:
      hal-01830094; https://hal.science/hal-01830094; https://hal.science/hal-01830094/document; https://hal.science/hal-01830094/file/980825.pdf
    • الرقم المعرف:
      10.1155/2013/980825
    • الدخول الالكتروني :
      https://hal.science/hal-01830094
      https://hal.science/hal-01830094/document
      https://hal.science/hal-01830094/file/980825.pdf
      https://doi.org/10.1155/2013/980825
    • Rights:
      http://creativecommons.org/licenses/by/ ; info:eu-repo/semantics/OpenAccess
    • الرقم المعرف:
      edsbas.E92D1B9C