Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Precurved non-tunnelled catheters for haemodialysis are comparable in terms of infections and malfunction as compared to tunnelled catheters:A retrospective cohort study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2019
    • Collection:
      Maastricht University Research Publications
    • نبذة مختصرة :
      Background: The main limitations of central venous catheters for haemodialysis access are infections and catheter malfunction. Our objective was to assess whether precurved non-tunnelled central venous catheters are comparable to tunnelled central venous catheters in terms of infection and catheter malfunction and to assess whether precurved non-tunnelled catheters are superior to straight catheters. Materials and methods: In this retrospective, observational cohort study, adult patients in whom a central venous catheter for haemodialysis was inserted between 2012 and 2016 were included. The primary endpoint was a combined endpoint consisting of the first occurrence of either an infection or catheter malfunction. The secondary endpoint was a combined endpoint of the removal of the central venous catheter due to either an infection or a catheter malfunction. Using multivariable analysis, cause-specific hazard ratios for endpoints were calculated for tunnelled catheter versus precurved non-tunnelled catheter, tunnelled catheter versus non-tunnelled catheter, and precurved versus straight non-tunnelled catheter. Results: A total of 1603 patients were included. No difference in reaching the primary endpoint was seen between tunnelled catheters, compared to precurved non-tunnelled catheters (hazard ratio, 0.91; 95% confidence interval, 0.70-1.19, p = 0.48). Tunnelled catheters were removed less often, compared to precurved non-tunnelled catheters (hazard ratio, 0.65; 95% confidence interval, 0.46-0.93; p = 0.02). A trend for less infections and catheter malfunctions was seen in precurved jugular non-tunnelled catheters compared to straight non-tunnelled catheters (hazard ratio, 0.60; 95% confidence interval, 0.24-1.50; p = 0.28) and were removed less often (hazard ratio, 0.41; 95% confidence interval, 0.18-0.93; p = 0.03). Conclusion: Tunnelled central venous catheters and precurved non-tunnelled central venous catheters showed no difference in reaching the combined endpoint of catheter-related infections and ...
    • الرقم المعرف:
      10.1177/1129729818805954
    • الدخول الالكتروني :
      https://cris.maastrichtuniversity.nl/en/publications/6945fb0f-f83d-4227-89b4-5984f61d94d3
      https://doi.org/10.1177/1129729818805954
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.E65AD0B5