Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Contrast-Enhanced Ultrasound (CEUS) for the Evaluation of Bosniak III Complex Renal Cystic Lesions—A 10-Year Specialized European Single-Center Experience with Histopathological Validation

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      MDPI AG
    • الموضوع:
      2020
    • Collection:
      Directory of Open Access Journals: DOAJ Articles
    • نبذة مختصرة :
      Background and objectives : The aim of the present retrospective single-center study is to evaluate the diagnostic performance of contrast-enhanced ultrasound (CEUS) for assessing Bosniak III complex renal cystic lesions with histopathological validation. Materials and Methods : 49 patients with CEUS-categorized Bosniak III renal cystic lesions were included in this retrospective study. All patients underwent native B-mode, Color Doppler, contrast-enhanced ultrasound (CEUS) between 2010–2020. Eight and five patients underwent computed tomography (CT) and magnetic resonance imaging (MRI), respectively. Twenty-nine underwent (partial) nephrectomy allowing for histopathological analysis. The applied contrast agent for CEUS was a second-generation blood pool agent. Ultrasonography examinations were performed and interpreted by a single experienced radiologist with more than 15 years of experience (EFSUMB Level 3). Results : CEUS examinations were successfully performed in all included patients without registering any adverse effects. The malignancy rate of CEUS-categorized Bosniak III renal lesions accounted for 66%. Initially, cystic complexity was visualized in native B-mode. In none of the renal lesions hypervascularization was detected in Color Doppler. CEUS allowed for detection of contrast enhancement patterns in all included Bosniak III renal lesions. Delayed wash-out could be detected in 6/29 renal lesions. In two cases of histopathologically confirmed clear-cell RCC, appropriate up-grading from Bosniak IIF to III was achieved by CEUS. Conclusions : CEUS depicts a promising imaging modality for the precise diagnostic workup and stratification of renal cystic lesions according to the Bosniak classification system, thereby helping guidance of adequate clinical management in the future.
    • ISSN:
      1648-9144
      1010-660X
    • Relation:
      https://www.mdpi.com/1648-9144/56/12/692; https://doaj.org/toc/1010-660X; https://doaj.org/toc/1648-9144; https://doaj.org/article/e86d26ecbd49490f83a8431464d4ae3d
    • الرقم المعرف:
      10.3390/medicina56120692
    • الرقم المعرف:
      edsbas.E64EBF5D