Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

A liquid chromatography coupled to tandem mass spectrometry method for the quantification of spiramycin and its active metabolite neospiramycin in milk of major and minor species: Validation using the accuracy profile

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Pharmacologie des anti-infectieux (PHAR Poitiers ); Université de Poitiers = University of Poitiers (UP)-Institut National de la Santé et de la Recherche Médicale (INSERM); Laboratoire de Fougères - ANSES; Agence nationale de sécurité sanitaire de l'alimentation, de l'environnement et du travail (ANSES); Centre hospitalier universitaire de Poitiers = Poitiers University Hospital (CHU de Poitiers La Milétrie ); CEVA Animal Halth; Région Nouvelle Aquitaine
    • بيانات النشر:
      HAL CCSD
      Elsevier
    • الموضوع:
      2021
    • Collection:
      Université de Poitiers: Publications de nos chercheurs.ses (HAL)
    • نبذة مختصرة :
      International audience ; A liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous quantification of residues of spiramycin, a macrolide antibiotic, and its active metabolite neospiramycin in cow's milk as well as in minor species milk, goat and ewe. Spiramycin-d3 was used as internal standard for quantification of both analytes. This analytical method was validated using a global accuracy profile as a graphical decision tool built according to the trueness and the precision of the method. A unique and optimal linear model with logarithm transformation (with a determination coefficient of 0.9991) allowed the measurement of both analytes in the milks of the three animal species, in a wide range from 0.2 to 10 times the Maximal Residue Limit (MRL) (40-2000 µg.kg(-1)). The limits of detection and quantification were 13 µg.kg(-1) and 40 µg.kg(-1), respectively. The accuracy profile was established to get 80% of future measurements in routine assays that will fall within the acceptance limits. Trueness of the method, expressed as relative bias, was comprised between -1.6% and 5.7% over the whole range of concentrations. The mean relative standard deviation for repeatability and intermediate precision were comprised between 1.1% and 2.7%; 2.5 and 4.2%, respectively, in all levels of concentration for the three milks. Moreover, a two-order polynomial function was used to model the relative expanded uncertainty with a determination coefficient of 0.834. This function aimed to determine the uncertainty of the future quantifications within the validated dosing range. Overall, the global accuracy profile highlighted the reliability of the method for the routine assays of spiramycin and neospiramycin even in milk from minor species (goat, ewe) by using the most accessible milk (often from cow), while guaranteeing a very high proportion of samples within the fixed acceptance limits. The applicability of this method was tested during a depletion study of spiramycin and ...
    • Relation:
      info:eu-repo/semantics/altIdentifier/pmid/34808577; anses-03461263; https://anses.hal.science/anses-03461263; https://anses.hal.science/anses-03461263/document; https://anses.hal.science/anses-03461263/file/S1570023221004943.pdf; PII: S1570-0232(21)00494-3; PUBMED: 34808577
    • الرقم المعرف:
      10.1016/j.jchromb.2021.123013
    • الدخول الالكتروني :
      https://anses.hal.science/anses-03461263
      https://anses.hal.science/anses-03461263/document
      https://anses.hal.science/anses-03461263/file/S1570023221004943.pdf
      https://doi.org/10.1016/j.jchromb.2021.123013
    • Rights:
      http://creativecommons.org/licenses/by-nc/ ; info:eu-repo/semantics/OpenAccess
    • الرقم المعرف:
      edsbas.E3B97231