Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Differential privacy preserved federated transfer learning for multi-institutional 68 Ga-PET image artefact detection and disentanglement

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2023
    • Collection:
      University of Southern Denmark: Research Output / Syddansk Universitet
    • نبذة مختصرة :
      Purpose: Image artefacts continue to pose challenges in clinical molecular imaging, resulting in misdiagnoses, additional radiation doses to patients and financial costs. Mismatch and halo artefacts occur frequently in gallium-68 ( 68 Ga)-labelled compounds whole-body PET/CT imaging. Correcting for these artefacts is not straightforward and requires algorithmic developments, given that conventional techniques have failed to address them adequately. In the current study, we employed differential privacy-preserving federated transfer learning (FTL) to manage clinical data sharing and tackle privacy issues for building centre-specific models that detect and correct artefacts present in PET images. Methods: Altogether, 1413 patients with 68 Ga prostate-specific membrane antigen (PSMA)/DOTA-TATE (TOC) PET/CT scans from 3 countries, including 8 different centres, were enrolled in this study. CT-based attenuation and scatter correction (CT-ASC) was used in all centres for quantitative PET reconstruction. Prior to model training, an experienced nuclear medicine physician reviewed all images to ensure the use of high-quality, artefact-free PET images (421 patients’ images). A deep neural network (modified U2Net) was trained on 80% of the artefact-free PET images to utilize centre-based (CeBa), centralized (CeZe) and the proposed differential privacy FTL frameworks. Quantitative analysis was performed in 20% of the clean data (with no artefacts) in each centre. A panel of two nuclear medicine physicians conducted qualitative assessment of image quality, diagnostic confidence and image artefacts in 128 patients with artefacts (256 images for CT-ASC and FTL-ASC). Results: The three approaches investigated in this study for 68 Ga-PET imaging (CeBa, CeZe and FTL) resulted in a mean absolute error (MAE) of 0.42 ± 0.21 (CI 95%: 0.38 to 0.47), 0.32 ± 0.23 (CI 95%: 0.27 to 0.37) and 0.28 ± 0.15 (CI 95%: 0.25 to 0.31), respectively. Statistical analysis using the Wilcoxon test revealed significant differences between the three ...
    • File Description:
      application/pdf
    • الرقم المعرف:
      10.1007/s00259-023-06418-7
    • الدخول الالكتروني :
      https://portal.findresearcher.sdu.dk/da/publications/346ed94c-ba9d-4f00-9a53-287aab96ac16
      https://doi.org/10.1007/s00259-023-06418-7
      https://findresearcher.sdu.dk/ws/files/246193205/s00259_023_06418_7.pdf
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.DBEB8E76