Adapting a practical EPR dosimetry protocol to measure output factors in small fields with alanine.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Höfel, Sebastian; Liebig, Pauline; Fix, Michael K; Drescher, Malte; Zwicker, Felix
  • المصدر:
    Höfel, Sebastian; Liebig, Pauline; Fix, Michael K; Drescher, Malte; Zwicker, Felix (2023). Adapting a practical EPR dosimetry protocol to measure output factors in small fields with alanine. Journal of applied clinical medical physics, 24(12), e14191. American Association of Physicists in Medicine 10.1002/acm2.14191
  • الموضوع:
  • نوع التسجيلة:
    article in journal/newspaper
  • اللغة:
    English
  • معلومة اضافية
    • بيانات النشر:
      American Association of Physicists in Medicine
    • الموضوع:
      2023
    • Collection:
      BORIS (Bern Open Repository and Information System, University of Bern)
    • نبذة مختصرة :
      PURPOSE Modern radiotherapy techniques often deliver small radiation fields. In this work, a practical Electron Paramagnetic Resonance (EPR) dosimetry protocol is adapted and applied to measure output factors (OF) in small fields of a 6 MV radiotherapy system. Correction factors and uncertainties are presented and OFs are compared to the values obtained by following TRS-483 using an ionization chamber (IC). METHODS Irradiations were performed at 10 cm depth inside a water phantom positioned at 90 cm source to surface distance with a 6 MV flattening filter free photon beam of a Halcyon radiotherapy system. OFs for different nominal field sizes (1 × 1, 2 × 2, 3 × 3, 4 × 4, normalized to 10 × 10 cm2 ) were determined with a PinPoint 3D (PTW 31022) IC following TRS-483 as well as with alanine pellets with a diameter of 4 mm and a height of 2.4 mm. EPR readout was performed with a benchtop X-band spectrometer. Correction factors due to volume averaging and due to positional uncertainties were derived from 2D film measurements. RESULTS OFs obtained from both dosimeter types agreed within 0.7% after applying corrections for the volume averaging effect. For the used alanine pellets, volume averaging correction factors of 1.030(2) for the 1 × 1 cm2 field and <1.002 for the larger field sizes were determined. The correction factor for positional uncertainties of 1 mm was in the order of 1.018 for the 1 × 1 cm2 field. Combined relative standard uncertainties uc for the OFs resulting from alanine measurements were estimated to be below 1.5% for all field sizes. For IC measurements, uc was estimated to be below 1.0%. CONCLUSIONS A practical EPR dosimetry protocol is adaptable for precisely measuring OFs in small fields down to 1 × 1 cm2 . It is recommended to consider the effect of positional uncertainties for field sizes <2 × 2 cm2 .