Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Flow rate accuracy of infusion devices within healthcare settings: a systematic review

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      SAGE Publishing
    • الموضوع:
      2023
    • Collection:
      Imperial College London: Spiral
    • نبذة مختصرة :
      Background: One in five patients admitted to the hospital treated with intravenous (IV) fluid therapy suffer complications due to inappropriate administration. Errors have been reported in 13–84% of the preparation and administration of IV medications. The safe delivery of IV fluids requires precise rate administration. Objectives: This systematic review aims to determine the accuracy of infusion sets and devices and examine the factors that affect the flow rate accuracy of devices. Data Sources and Methods: Six databases (CINAHL, MEDLINE PubMed, EMBASE, Web of Science and Cochrane Database of systematic reviews) were systematically searched. Search terms included infusion pumps, infusion devices, flow rate accuracy, fluid administration rate, gravity-led infusion set and fluid balance. Studies were included if they examined infusion devices’ flow rate accuracy and drop rates for fluids or non-oncological drugs. Findings were tabulated and synthesised qualitatively. The quality of the studies was examined based on the design of the studies due to their heterogeneity. Results: Eight studies were included: Four studies were conducted on human subjects in the hospital environment; studies recruited 182 participants between the ages of 18 and 94 years. Two studies examined flow rate accuracy in recruited patients across 509 observations and 2387 drip hours. No trials prospectively assessed the accuracy of infusion pumps in the clinical domain, and no studies were reported on patient safety outcomes. Four studies examined the impact of mechanical and physiological factors on the flow rate accuracies of infusion devices. Height and back pressure simulated vibrating conditions, the viscosity of IV fluid and the positions of patients were reported to have a significant impact on infusion volume and flow rates of infusion devices. Additionally, giving sets that vary from the manufacturer’s specifications are reported to increase error percent by 10–20%. Conclusion: Infusion devices are an important source of error in ...
    • ISSN:
      2042-0986
    • Relation:
      Therapeutic Advances in Drug Safety; http://hdl.handle.net/10044/1/105309
    • الرقم المعرف:
      10.1177/20420986231188602
    • Rights:
      © The Author(s), 2023. Article reuse guidelines: sagepub.com/journalspermissions. Creative Commons CC BY: This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the Sage and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). ; https://creativecommons.org/licenses/by/4.0/
    • الرقم المعرف:
      edsbas.CABCBE04