Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Inter-visit Test-retest Variability of the Topcon 3D OCT-2000 in Glaucoma

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • المؤلفون: Pearce, John; Maddess, Ted
  • المصدر:
    Optometry and Vision Science
  • نوع التسجيلة:
    article in journal/newspaper
  • اللغة:
    English
  • معلومة اضافية
    • بيانات النشر:
      Lippincott Williams & Wilkins
    • Collection:
      Australian National University: ANU Digital Collections
    • نبذة مختصرة :
      Purpose. To determine the inter-visit test-retest variability (TRV) of a spectral domain optical coherence tomograph, the Topcon 3D OCT-2000, in the measurement of optic nerve head topography, peripapillary retinal nerve fiber layer (pRNFL), and macular ganglion cell complex (GCC) parameters in glaucoma patients.We also examine whether TRV with this instrument varies with the extent of glaucomatous damage. Methods. Twenty-four subjects with varying degrees of glaucoma severity provided 41 eyes with usable results for the study. 3D Disc Retinal Nerve Fiber Layer Analysis and Macula V (GCC) scans were repeated 1 week apart, at the same time of day, to determine the inter-visit TRV. TRV was determined using Bland-Altman limits of agreement (LoA) and the resulting coefficients of repeatability (CR). Results. The overall horizontal and vertical cup/disc ratio CRs were 0.05 and 0.07, respectively. The GCC CR was 2.9 Km. In contrast, average pRNFL TRV expanded with increasing damage, with the LoA being well fitted by T(34.67 j 0.294(d)), where d is the pRNFL thickness. A more complex model, with constant LoA of T5.61 Km at d 982 Km, and linearly expanding TRV below that, achieved marginal significance (p G 0.06). Conclusions. The repeatability of GCC measurements with this instrument was excellent. The determination of statistically significant change in average pRNFL should take into account average pRNFL thickness. (Optom Vis Sci 2017;94:00Y00) ; This research was supported by the Australian Research Council through the ARC Centre of Excellence in Vision Science (CE0561903) and the Australian Federal Government through the Nursing and Allied Health Scholarship Support Scheme
    • File Description:
      application/pdf
    • ISSN:
      1040-5488
    • Relation:
      http://purl.org/au-research/grants/arc/CE0561903; http://hdl.handle.net/1885/240572; https://openresearch-repository.anu.edu.au/bitstream/1885/240572/3/01_Pearce_Inter-visit_Test-retest_2017.pdf.jpg
    • الرقم المعرف:
      10.1097/OPX.0000000000001022
    • الدخول الالكتروني :
      http://hdl.handle.net/1885/240572
      https://doi.org/10.1097/OPX.0000000000001022
      https://openresearch-repository.anu.edu.au/bitstream/1885/240572/3/01_Pearce_Inter-visit_Test-retest_2017.pdf.jpg
    • Rights:
      © 2016 American Academy of Optometry
    • الرقم المعرف:
      edsbas.B7EBC252