Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758) ; Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758)

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Pippi, Ney Luis; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783382P7; Mazzanti, Alexandre; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4795593E6; Rossi, Alvaro Garcia; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4784143D7; Godoy, Carmen Lice Buchmann de; http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790150U6
    • بيانات النشر:
      Universidade Federal de Santa Maria
      BR
      Medicina Veterinária
      UFSM
      Programa de Pós-Graduação em Medicina Veterinária
    • الموضوع:
      2005
    • Collection:
      Manancial - Repositório Digital da UFSM (Universidade Federal de Santa Maria)
    • نبذة مختصرة :
      Veterinary medicine is benefitted by technological advances in diagnostic area by the spreading of scientific knowlagement. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objectives of this study were to verify the Doppler ultrasound flow of the external ophthalmic artery in mixed breed cats anesthetized with tiletamine and zolazepam, and to correlate the average mean arterial pressure (MAP) surveyed by direct method in the same animals. There were used 20 mixed breed cats, both male and female, with body mass between 2 and 4 kilograms, proceeding from the Sociedade de Auxílio aos Animais de Umuarama - PR (SAAU). The animals received intra-muscular anesthesia with tiletamine and zolazepam (6,0 mg/kg). The femoral artery was assepticale cannulated and a manometer connected to an air column was connected to the catheter. The MAP was surveyed before and every 15 minutes until the end of the ultrasound examination. The flow of the external ophthalmic artery was measured through the ultrasond equipment Toshiba Powervision ATLHDI 3500, with an echo-doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery flow surveyed by the equipment s own device, 3 samples being taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic flow of each vasses. The values were tabulated and Student t test was applied to verify differences between the averages. Test of logistic regression was applied to the values of the MAP and the means of the artery flow to verify the correlation between the surveyed values. An average value for the MAP of 144.9 ± 26.68 mmHg and a flow of 14.28 ± 41.3 cm/sec for the external ophthalmic artery in the right eye in systole, 23.95 ± 11.46 cm/sec in diastole and 42.75 ± ...
    • File Description:
      application/pdf
    • Relation:
      GONÇALVES, Gentil Ferreira. Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758). 2005. 80 f. Tese (Doutorado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2005.; http://repositorio.ufsm.br/handle/1/4022
    • Rights:
      Acesso Aberto
    • الرقم المعرف:
      edsbas.AE4259DF