Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Analysis of the evolution of ultra-filtered water quality in a drinking water distribution system by particle size distribution: Influence of pre-ozonation

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2023
    • Collection:
      DIGIBUG: Repositorio Institucional de la Universidad de Granada
    • نبذة مختصرة :
      An experimental drinking water distribution system (DWDS) was used to evaluate the evolution of particle size distribution (PSD) and basic quality parameters of ultrafiltered water with or without pre-ozonation. An ultrafiltration (UF) module was set up, associated with a pre-ozonation system (3.7 g O3/m3). The permeate was circulated in the DWDS (300 m; 0.9 m/s) with 0.4 mg/L of chlorine, and the analysis of the PSD was performed using a β-variable mathematical model. A better control of membrane fouling was obtained with preozonation, and PSD was necessary to observe water quality differences between permeates and in the DWDS. A decrease in particle concentration of 1.8 logarithms was obtained with the application of UF membranes, while a decrease of only 1.2 logarithms was obtained with pre-ozonation. The system without pre-ozonation showed a higher efficiency at removing smaller particles (around 2 μm), with the absence of particles larger than 23 μm during both stages. The PSD revealed a worsening of water quality in the DWDS with an increase of particles smaller than 5 μm during the application of UF membranes, while with pre-ozonation, all particle sizes analyzed increased their concentration. Practitioner Points • Pre-ozonation led to a better control of membrane fouling, but a worsening of permeate quality according to particle size distribution. • Pre-ozonation does not improve the turbidity, dissolved organic carbon or UV254 removal capacity of ultrafiltration during drinking water treatment. • Particles size distribution reveals the deterioration of water quality in a drinking water distribution system better than turbidity or DOC. • Ozone prior to ultrafiltration membranes led to a worsening of permeate quality, more significant in the drinking water distribution system. ; Spanish Ministry of Science and Innovation, Grant/Award Number: CTM2010-18899-TECNO
    • Relation:
      Álvarez‐Arroyo, R., Pérez, J. I., Ruiz, L. M., & Gómez, M. Á. (2023). Analysis of the evolution of ultra‐filtered water quality in a drinking water distribution system by particle size distribution: Influence of pre‐ozonation. Water Environment Research, 95(2), e10840.[https://doi.org/10.1002/wer.10840]; https://hdl.handle.net/10481/82844
    • الرقم المعرف:
      10.1002/wer.10840
    • الدخول الالكتروني :
      https://hdl.handle.net/10481/82844
      https://doi.org/10.1002/wer.10840
    • Rights:
      Attribution-NonCommercial-NoDerivatives 4.0 Internacional ; http://creativecommons.org/licenses/by-nc-nd/4.0/ ; info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.AA814CB