Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Performance of ultralow-dose CT with iterative reconstruction in lung cancer screening: limiting radiation exposure to the equivalent of conventional chest X-ray imaging.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Springer
    • الموضوع:
      2016
    • Collection:
      BORIS (Bern Open Repository and Information System, University of Bern)
    • نبذة مختصرة :
      OBJECTIVE To investigate the detection rate of pulmonary nodules in ultralow-dose CT acquisitions. MATERIALS AND METHODS In this lung phantom study, 232 nodules (115 solid, 117 ground-glass) of different sizes were randomly distributed in a lung phantom in 60 different arrangements. Every arrangement was acquired once with standard radiation dose (100 kVp, 100 references mAs) and once with ultralow radiation dose (80 kVp, 6 mAs). Iterative reconstruction was used with optimized kernels: I30 for ultralow-dose, I70 for standard dose and I50 for CAD. Six radiologists examined the axial 1-mm stack for solid and ground-glass nodules. During a second and third step, three radiologists used maximum intensity projection (MIPs), finally checking with computer-assisted detection (CAD), while the others first used CAD, finally checking with the MIPs. RESULTS The detection rate was 95.5 % with standard dose (DLP 126 mGy*cm) and 93.3 % with ultralow-dose (DLP: 9 mGy*cm). The additional use of either MIP reconstructions or CAD software could compensate for this difference. A combination of both MIP reconstructions and CAD software resulted in a maximum detection rate of 97.5 % with ultralow-dose. CONCLUSION Lung cancer screening with ultralow-dose CT using the same radiation dose as a conventional chest X-ray is feasible. KEY POINTS • 93.3 % of all lung nodules were detected with ultralow-dose CT. • A sensitivity of 97.5 % is possible with additional image post-processing. • The radiation dose is comparable to a standard radiography in two planes. • Lung cancer screening with ultralow-dose CT is feasible.
    • File Description:
      application/pdf
    • Relation:
      https://boris.unibe.ch/94054/
    • الدخول الالكتروني :
      https://boris.unibe.ch/94054/1/art%253A10.1007%252Fs00330-015-4192-3.pdf
      https://boris.unibe.ch/94054/8/Main%20Document_postprint.pdf
      https://boris.unibe.ch/94054/
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.A473005C