Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Psychometric Properties of the NEI-RQL-42 Questionnaire in Keratoconus

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Flinders Med Ctr; Flinders Univ S Australia; Universidade Federal de São Paulo (UNIFESP)
    • بيانات النشر:
      Assoc Research Vision Ophthalmology Inc
    • الموضوع:
      2012
    • Collection:
      Universidade Federal de São Paulo (UNIFESP): Repositório Institucional
    • نبذة مختصرة :
      PURPOSE. To assess the psychometric properties of the National Eye Institute Refractive Error Quality of Life (NEI-RQL-42) questionnaire in keratoconus and compare these findings to patients with refractive error correction alone.METHODS. the Portuguese version of the NEI-RQL-42 Quality of Life questionnaire was completed by 44 patients who had keratoconus before and after implantation of intracorneal ring segments. Rasch analysis was used to assess the use of response categories, success in measuring a single trait per subscale (unidimensionality), ability to discriminate person ability (precision), and targeting of questions to person quality of life (QoL).RESULTS. Rasch analysis was performed for the questionnaire subscales using stacked preoperative and postoperative data. Three subscales (Symptoms, Dependence on correction, and Suboptimal correction) contained response categories that were not used as intended. Six subscales contained misfitting items indicating multidimensionality. Eleven subscales exhibited inadequate measurement precision. Only the Near vision subscale demonstrated adequate precision with a person separation greater than 2.0. Targeting of items to person QoL was adequate in 11 of the 12 subscales with a mean item location of less than 1 logit.CONCLUSIONS. Only one NEI-RQL-42 subscale (Near vision) performed adequately in keratoconus. Targeting was better in patients with keratoconus than in patients with refractive error correction alone, but 11 of the 12 subscales remain manifestly inadequate. Better instruments exist for measuring patient-reported outcomes in keratoconus. (Invest Ophthalmol Vis Sci. 2012; 53:7370-7374) DOI:10.1167/iovs.12-9969 ; Flinders Med Ctr, NH&MRC Ctr Clin Eye Res, Bedford Pk, SA 5042, Australia ; Flinders Univ S Australia, Bedford Pk, SA 5042, Australia ; Universidade Federal de São Paulo, São Paulo, Brazil ; Universidade Federal de São Paulo, EPM, São Paulo, Brazil ; Web of Science
    • File Description:
      7370-7374
    • ISSN:
      0146-0404
    • Relation:
      Investigative Ophthalmology & Visual Science; http://dx.doi.org/10.1167/iovs.12-9969; Investigative Ophthalmology & Visual Science. Rockville: Assoc Research Vision Ophthalmology Inc, v. 53, n. 11, p. 7370-7374, 2012.; http://repositorio.unifesp.br/handle/11600/35322; WOS:000310589900087
    • الرقم المعرف:
      10.1167/iovs.12-9969
    • Rights:
      Acesso aberto
    • الرقم المعرف:
      edsbas.A3B0FBA8