Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Additional erythrocytic and reticulocytic parameters helpful for diagnosis of hereditary spherocytosis: results of a multicentre study.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      UCL - SSS/IREC/MONT - Pôle Mont Godinne; UCL - SSS/IREC/MIRO - Pôle d'imagerie moléculaire, radiothérapie et oncologie; UCL - (MGD) Laboratoire de biologie clinique; UCL - (MGD) Service d'hématologie
    • بيانات النشر:
      Springer
    • الموضوع:
      2011
    • Collection:
      DIAL@USL-B (Université Saint-Louis, Bruxelles)
    • نبذة مختصرة :
      Hereditary spherocytosis (HS) is characterised by weakened vertical linkages between the membrane skeleton and the red blood cell's lipid bilayer, leading to the release of microparticles. All the reference tests suffer from specific limitations. The aim of this study was to develop easy to use diagnostic tool for screening of hereditary spherocytosis based on routinely acquired haematological parameters like percentage of microcytes, percentage of hypochromic cells, reticulocyte counts, and percentage of immature reticulocytes. The levels of haemoglobin, mean cell volume, mean corpuscular haemoglobin concentration, reticulocytes (Ret), immature reticulocytes fraction (IRF), hypochromic erythrocytes (Hypo-He) and microcytic erythrocytes (MicroR) were determined on EDTA samples on Sysmex instruments from a cohort of 45 confirmed SH. The HS group was then compared with haemolytical disorders, microcytic anaemia, healthy individuals and routine samples (n = 1,488). HS is characterised by a high Ret count without an equally elevated IRF. All 45 HS have Ret >80,000/μl and Ret(10(9)/L)/IRF (%) greater than 7.7 (rule 1). Trait and mild HS had a Ret/IRF ratio greater than 19. Moderate and severe HS had increased MicroR and MicroR/Hypo-He (rule 2). Combination of both rules gave predictive positive value and negative predictive value of respectively 75% and 100% (n=1,488), which is much greater than single parameters or existing rules. This simple and fast diagnostic method could be used as an excellent screening tool for HS. It is also valid for mild HS, neonates and ABO incompatibilities and overcomes the lack of sensitivity of electrophoresis in ankyrin deficiencies.
    • ISSN:
      0939-5555
      1432-0584
    • Relation:
      boreal:123908; http://hdl.handle.net/2078.1/123908; info:pmid/21181161; urn:ISSN:0939-5555; urn:EISSN:1432-0584
    • الرقم المعرف:
      10.1007/s00277-010-1138-3
    • Rights:
      info:eu-repo/semantics/restrictedAccess
    • الرقم المعرف:
      edsbas.A0D75783