Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Pulmonary vein isolation with the radiofrequency balloon catheter: long-term results and predictors of ablation success

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Oxford University Press (OUP)
    • الموضوع:
      2024
    • نبذة مختصرة :
      Background The novel multielectrode radiofrequency balloon catheter (RFB) has been demonstrated to achieve safe and effective pulmonary vein isolation (PVI). However, data on long-term ablation outcomes is lacking. Purpose This single-centre study aimed to evaluate the efficacy of the RFB beyond 1-year follow-up and define predictors of arrhythmia recurrence. Methods All consecutive patients with symptomatic paroxysmal atrial fibrillation (AF) undergoing first-time PVI with the RFB between January 2021 and November 2022 were prospectively included. Post-ablation remapping was systematically employed to confirm PVI at the end of the procedure. Procedural failure was defined as any atrial tachyarrhythmias (ATas) lasting >30 s occurring during the follow-up after a 3-month blanking period (BP). Patient characteristics, procedural parameters, and ATas recurrence during BP were analysed with respect to ablation outcome. Results A total of 120 consecutive patients (50 female, 42%; mean age 65±12 years) were enrolled. After a mean follow-up of 16.1±7.9 months, ATas recurrence occurred in 30 patients (25%). ATas were adjudicated as AF in 25 patients (83.3%) and as atrial tachycardia/atrial flutter in 5 patients (16.7%). The mean time from the index procedure to ATas recurrence was 203±130 days. A redo procedure was performed in 17 patients (56.7%) and at least one PV reconnection was observed in 12 patients (70.6%). Patients with ATas recurrence presented higher values of body mass index (31.0 ±5.7 vs. 28.1±4.9 kg/m2, p=0.048), larger left atria (43±11 vs. 35±9 ml/m2, p=0.003), and increased rates of ATas recurrence during the BP (53.3% vs. 2.2 %, p<0.001) compared to patients with persistent sinus rhythm. At multivariable Cox regression analysis, left atrial end-systolic volume index and ATas recurrence during the BP were independently associated with procedural failure (HR 1.05, 95%CI 1.00-1.11, p=0.048 and HR 23.88, 95%CI 7.71-73.99, p<0.001, respectively). Conclusion At 16 months ...
    • الرقم المعرف:
      10.1093/europace/euae102.752
    • الدخول الالكتروني :
      http://dx.doi.org/10.1093/europace/euae102.752
      https://academic.oup.com/europace/article-pdf/26/Supplement_1/euae102.752/57875927/euae102.752.pdf
    • Rights:
      https://creativecommons.org/licenses/by-nc/4.0/
    • الرقم المعرف:
      edsbas.9252327E