Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Valor predictor del cociente saturación hemoglobina/FiO2 en pacientes pediátricos con insuficiencia respiratoria aguda debida a neumonía tratados con ventilación no invasiva ; Predictive value of the pulse oximetric saturation/fraction of inspired oxygen ratio in pediatric patients with acute respiratory failure due to pneumonia treated with non-invasive ventilation

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Pons Ódena, Martí; Universidad de Cantabria
    • الموضوع:
      2014
    • Collection:
      Universidad de Cantabria: UCrea
    • نبذة مختصرة :
      RESUMEN: El uso de la ventilación no invasiva (VNI) en pacientes con fracaso respiratorio hipoxémico debido a neumonía es controvertido, alcanzando elevadas tasas de fracaso en el Síndrome de Distrés Respiratorio Agudo (SDRA). Recientemente, el cociente SpO2/FiO2 (SF) se ha equiparado al cociente paO2/FiO2 (PF) para la valoración del SDRA. Determinamos en una cohorte de pacientes, diagnosticados de neumonía y tratados con VNI, si el cociente SF es una variable con valor predictor de fracaso durante las primeras horas y clasificamos mediante dicho cociente el SDRA según la última definición de Berlín (leve, moderado, grave) para identificar aquellos pacientes de mayor riesgo. La tasa global de éxito de la VNI fue del 77%. Tanto el cociente SF como la FC a las 2h se identificaron como factores predictores independientes de fracaso. El diagnóstico de SDRA mediante el cociente SF, podría utilizarse para identificar a una población más susceptible de fracaso. ; ABSTRACT: The use of non-invasive ventilation (NIV) in patients with hypoxemic acute respiratory failure (ARF) due to pneumonia is discussed. The most frequent cause of ARF was pneumonia and acute respiratory distress syndrome (ARDS) was the main cause of treatment failure. A good correlation between SF ratio (SpO2/FiO2) and PF ratio (paO2/FiO2) was recently confirmed. We aimed to evaluate if the SF ratio is a reliable predictive factor for NIV failure in pediatric patients with moderate hypoxemic ARF due to pneumonia and could classify ARDS according to the recent Berlin definition (mild, moderate and severe) to identify high-risk children. Our NIV success rate was 77%. SF ratio and heart rate at two hours were found to be independent predictors of NIV failure. The diagnosis of ARDS based on the SF ratio was not identified as an independent NIV outcome predictor. However, it may be useful in classifying high-risk children.
    • Relation:
      http://hdl.handle.net/10803/276848; http://hdl.handle.net/10902/5318
    • الدخول الالكتروني :
      http://hdl.handle.net/10902/5318
    • Rights:
      Atribución-NoComercial-SinDerivadas 3.0 España ; http://creativecommons.org/licenses/by-nc-nd/3.0/es/ ; openAccess
    • الرقم المعرف:
      edsbas.7D29A3D1