Electrochemical Biosensor for the Determination of Specific Antibodies against SARS-CoV-2 Spike Protein

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Department of Physical Chemistry Vilnius; Vilnius University Vilnius; Center for Physical Sciences and Technology Vilnius (FTMC); Institut Européen des membranes (IEM); Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Université de Montpellier (UM)-Ecole Nationale Supérieure de Chimie de Montpellier (ENSCM); Université de Montpellier (UM)
    • بيانات النشر:
      HAL CCSD
      MDPI
    • الموضوع:
      2023
    • Collection:
      Université de Montpellier: HAL
    • نبذة مختصرة :
      International audience ; In this article, we report the development of an electrochemical biosensor for the determination of the SARS-CoV-2 spike protein (rS). A gold disc electrode was electrochemically modified to form the nanocrystalline gold structure on the surface. Then, it was further altered by a self-assembling monolayer based on a mixture of two alkane thiols: 11-mercaptoundecanoic acid (11-MUA) and 6-mercapto-1-hexanol (6-MCOH) (SAMmix). After activating carboxyl groups using a N-(3-dimethylaminopropyl)-N’-ethyl-carbodiimide hydrochloride and N-hydroxysuccinimide mixture, the rS protein was covalently immobilized on the top of the SAMmix. This electrode was used to design an electrochemical sensor suitable for determining antibodies against the SARS-CoV-2 rS protein (anti-rS). We assessed the association between the immobilized rS protein and the anti-rS antibody present in the blood serum of a SARS-CoV-2 infected person using three electrochemical methods: cyclic voltammetry, differential pulse voltammetry, and potential pulsed amperometry. The results demonstrated that differential pulse voltammetry and potential pulsed amperometry measurements displayed similar sensitivity. In contrast, the measurements performed by cyclic voltammetry suggest that this method is the most sensitive out of the three methods applied in this research.
    • Relation:
      hal-04056548; https://hal.umontpellier.fr/hal-04056548; https://hal.umontpellier.fr/hal-04056548/document; https://hal.umontpellier.fr/hal-04056548/file/ijms-24-00718-v3.pdf
    • الرقم المعرف:
      10.3390/ijms24010718
    • Rights:
      http://creativecommons.org/licenses/by/ ; info:eu-repo/semantics/OpenAccess
    • الرقم المعرف:
      edsbas.7536889E