Occupant UV Exposure Measurements for Upper-Room Ultraviolet Germicidal Irradiation ; J Photochem Photobiol B

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Milonova, Sonya; Rudnick, Stephen; McDevitt, James; Nardell, Edward
    • Collection:
      CDC Stacks (Centers for Disease Control and Prevention)
    • نبذة مختصرة :
      The threshold limit value (TLV) guideline for ultraviolet (UV) radiation specifies that irradiance measurements to ensure occupant safety be taken over an angle of 80° at the sensor. The purpose of this study was to evaluate the effect of an 80° field of view (FOV) tube on lower room UV-C irradiation measurements. Measurements were made in an experimental chamber at a height of 1.73m with and without an FOV tube. The FOV tube reduced the lower room irradiance readings by 18-34%, a statistically significant reduction compared to the bare sensor. An 80° FOV tube should be used for lower room irradiance measurements to comply with the TLV guideline. The resulting lower readings would allow more UV-C radiation in the upper room without compromising occupant safety. More UV-C radiation in the upper room could increase efficacy of UVGI systems for reducing transmission of airborne infectious diseases. In addition, recommendations are made to standardize lower room irradiance measurement techniques. ; D43 TW009379/TW/FIC NIH HHS/United States ; R01 OH009050/OH/NIOSH CDC HHS/United States ; 2017-06-01T00:00:00Z ; 27038734 ; PMC4854786
    • Relation:
      cdc:39295; http://stacks.cdc.gov/view/cdc/39295/
    • الدخول الالكتروني :
      http://stacks.cdc.gov/view/cdc/39295/
    • الرقم المعرف:
      edsbas.71EC4484