Pulse oximetry at two sensor placement sites in conscious foals

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Kliinisen hevos- ja pieneläinlääketieteen osasto; FaunaFysio; Eläinlääketieteellinen tiedekunnan osastot; Eläinlääketieteellinen tiedekunta
    • بيانات النشر:
      BioMed Central
    • الموضوع:
      2025
    • Collection:
      Helsingfors Universitet: HELDA – Helsingin yliopiston digitaalinen arkisto
    • نبذة مختصرة :
      Background Pulse oximetry has not been thoroughly evaluated for assessment of oxygenation in conscious foals. Compared with invasive arterial blood sampling, it is a painless and non-invasive method for real-time monitoring of blood oxygen saturation. The aim of this prospective clinical study was to evaluate the usability, validity, and reliability of pulse oximetry at two measuring sites (lip and caudal abdominal skin fold) for blood oxygen saturation measurement in conscious foals with and without respiratory compromise. Thirty-two foals under one month of age were used. Nineteen foals had normal respiratory and cardiovascular function, and 13 had pneumonia. Pulse oximetry with a transmittance sensor was performed in triplicate on each foal’s lip (n = 196 measurements) and/or skin fold (n = 338 measurements), and arterial blood sample was collected. The oxygen saturation values measured by pulse oximetry from the lip and skin fold were compared with each other (n = 58 measurement pairs) and with the calculated arterial oxygen saturation based on arterial blood samples (n = 93 measurement pairs). Furthermore, repeatability of the pulse oximetry measurements was assessed. Results Measured blood oxygen saturation was clearly associated with the calculated saturation, but on average (± SD) it was 1.8 (± 3.3) percentage units higher from the lip and 5.7 (± 4.3) percentage units higher from the skin fold than the calculated saturation. In concurrent lip and skin fold measurements within a foal, the skin fold measurements were 2.4 (± 2.4) percentage units higher than the lip measurements. The repeatability of three pulse oximetry saturation measurement results was moderate to good and significantly improved when the measurement furthest from the middle-measured value was excluded. The most deviating measurement was often obtained first. Pulse oximetry in general was well tolerated and easy to perform, but as expected in conscious foals, movement and contact problems generated occasional technical difficulties in ...
    • File Description:
      application/pdf
    • ISBN:
      978-0-01-403165-8
      0-01-403165-5
    • Relation:
      http://hdl.handle.net/10138/594077; 001403165500001
    • الدخول الالكتروني :
      http://hdl.handle.net/10138/594077
    • Rights:
      cc_by ; info:eu-repo/semantics/openAccess ; openAccess
    • الرقم المعرف:
      edsbas.6972CA5C