Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Early Experience with Inner Branch Stent–Graft System for Endovascular Repair of Thoraco-Abdominal and Pararenal Abdominal Aortic Aneurysm

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Multidisciplinary Digital Publishing Institute
    • الموضوع:
      2024
    • Collection:
      MDPI Open Access Publishing
    • نبذة مختصرة :
      Objectives: This study aims to evaluate the technical and clinical outcomes of the E-nside stent graft for thoraco-abdominal aortic aneurysm (TAAA) and pararenal abdominal aortic aneurysm (PAAA) endovascular treatment at our University Hospital Center. Methods: We conducted a retrospective analysis of patients electively treated by inner branched EVAR (iBEVAR) between 05/2021 and 03/2023. Demographic, procedural, and clinical data were analyzed. The technical success and clinical outcomes, such as access-site-related complications were reported. The perioperative and early mortality rate, freedom from aortic reintervention, target vessels’ (TVs) patency, and the endoleak rate were evaluated during the follow-up. The technical aspects (external iliac artery diameter, iliac tortuosity, extent of aortic coverage) were retrospectively analyzed. Results: Twenty-two patients were included (age 75.9 ± 5.5; 72.7% male). The aneurism extent was Crawford I = 4 (18.2%), III = 8 (36.4%), IV = 5 (22.7%), V = 1 (4.5%), and PAAA = 4 (18.2%). The mean aortic diameter was 63.5 ± 9.9 mm. The technical success was 95.5% (assisted primary success 100%). The clinical success was 86.4%. The perioperative and early freedom from all-cause mortality rates were 90.9% and 90%, respectively. No case of inter-stage aortic-related mortality was reported, and there was no permanent/temporary spinal cord ischemia (SCI). Seventy-eight out of 81 patent TVs were incorporated through a bridging stent (96.3%). The TV success was 95.1%. The mean external iliac artery (EIA) diameter was 7.5 ± 1.1 mm. Twelve patients (54.5%, including all female patients) were considered outside the instructions for use (IFU) due to narrow iliac arteries. One access-site-related complication was reported. Conclusions: Our experience confirms that E-nside has promising technical and clinical success rates, as well as a low reintervention rate, but it requires a significant compromise of the healthy aortic tissue and adequate iliac arteries that still represents a ...
    • File Description:
      application/pdf
    • Relation:
      Clinical Diagnosis and Prognosis; https://dx.doi.org/10.3390/diagnostics14232612
    • الرقم المعرف:
      10.3390/diagnostics14232612
    • الدخول الالكتروني :
      https://doi.org/10.3390/diagnostics14232612
    • Rights:
      https://creativecommons.org/licenses/by/4.0/
    • الرقم المعرف:
      edsbas.685B9869