Volumen Control vs. Presión Control: Repercusión Hemodinámica

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Editorial Ciencias Médicas
    • الموضوع:
      1999
    • Collection:
      Directory of Open Access Journals: DOAJ Articles
    • نبذة مختصرة :
      Se ha señalado, en la literatura, que las modalidades de ventilación reguladas por presión tienen ventajas conocidas sobre las modalidades controladas por volumen, sobre todo desde el punto de vista hemodinámico. Se estudiaron, partiendo de estos criterios, 30 pacientes que ingresaron en la Unidad de Cuidados Intensivos del CIMEQ, desde enero de 1996 y que requirieron ventilación mecánica como parte del tratamiento, pero que se encontraban hemodinámicamente estables y no tenían antecedentes de afecciones respiratorias. Se acoplaron a un respirador artifical (Servo 900 C o Servo 300) mediante cánula endotraqueal y se ventilaron durante 1 hora en régimen de volumen control, chequeando al término variables como compliance, presiones intrapulmonares, datos hemodinámicos (FC, PA, PVC, diuresis) y gasométricos. Durante la 2da. hora fueron ventilados en régimen de presión control y se evaluaron iguales parámetros de estudio. Se comprobó que la ventilación mecánica controlada por presión produjo menores repercusiones hemodinámicas en nuestros pacientes. It is stated in literature that the pressure control ventilation malaties have known advantages over the volumen control modalities, mainly from the hemodynamic point of view. Starting from this criterion, 30 patients who were admitted at the Intensive Care Unit of the Center of Medical and Surgical Research in January, 1996, and that required mechanical ventilation as part of the treatment were studied. These patients were hemodynamically stable and had no history of respiratory affections. They were coupled to an artificial respirator (Servo 900 C or Servo 300) by endotracheal tube and were ventilated for an hour under volume control regime. Variables such as compliance, intrapulmonary pressures, hemodynamic data (FC, PA, PVC, diuresis) and gasometric data were checked at the end. During the second hour they were ventilated under pressure control regime and the same parameters were evaluated. It was proved that mechanical pressure control ventilation produced less ...
    • ISSN:
      0034-7523
      1561-302X
    • Relation:
      http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0034-75231999000400005; https://doaj.org/toc/0034-7523; https://doaj.org/toc/1561-302X; https://doaj.org/article/2bfceb066330409db74e77b699671f51
    • الرقم المعرف:
      edsbas.63BE024A