Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Comparison between First-and Second-Generation Cryoballoon for Paroxysmal Atrial Fibrillation Ablation

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      C. Sergio; M. Massimo; F. Gaetano; F. Tundo; R. Stefania; D.R. Antonio; C. Michela; B. Majocchi; M. Vittoria; D.I. Pasquale; C. Valentina; P. Salvatore; C. Tondo
    • بيانات النشر:
      Hindawi
    • الموضوع:
      2016
    • Collection:
      The University of Milan: Archivio Istituzionale della Ricerca (AIR)
    • نبذة مختصرة :
      INTRODUCTION: Cryoballoon (CB) ablation has emerged as a novel treatment for pulmonary vein isolation (PVI) for patients with paroxysmal atrial fibrillation (PAF). The second-generation Arctic Front Advance (ADV) was redesigned with technical modifications aiming at procedural and outcome improvements. We aimed to compare the efficacy of the two different technologies over a long-term follow-up. METHODS: A total of 120 patients with PAF were enrolled. Sixty patients underwent PVI using the first-generation CB and 60 patients with the ADV catheter. All patients were evaluated over a follow-up period of 2 years. RESULTS: There were no significant differences between the two groups of patients. Procedures performed with the first-generation CB showed longer fluoroscopy time (36.3 ± 16.8 versus 14.2 ± 13.5 min, resp.; p = 0.00016) and longer procedure times as well (153.1 ± 32 versus 102 ± 24.8 min, resp.; p = 0.019). The overall long-term success was significantly different between the two groups (68.3 versus 86.7%, resp.; p = 0.017). No differences were found in the lesion areas of left and right PV between the two groups (resp., p = 0.61 and 0.57). There were no significant differences in procedural-related complications. CONCLUSION: The ADV catheter compared to the first-generation balloon allows obtaining a significantly higher success rate after a single PVI procedure during the long-term follow-up. Fluoroscopy and procedural times were significantly shortened using the ADV catheter.
    • Relation:
      info:eu-repo/semantics/altIdentifier/pmid/27069711; info:eu-repo/semantics/altIdentifier/wos/WOS:000373023400001; volume:2016; firstpage:1; lastpage:5; numberofpages:5; journal:CARDIOLOGY RESEARCH AND PRACTICE; http://hdl.handle.net/2434/534506; info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84962750593
    • الرقم المعرف:
      10.1155/2016/5106127
    • الدخول الالكتروني :
      https://doi.org/10.1155/2016/5106127
      http://hdl.handle.net/2434/534506
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.6215BE96