      The authors describe the methodology and results of dynamic field testing of the building of a universal pool under construction, as well as its eigenfrequencies, identified through the employment of a computer model. The subject of the research represents the building of a universal pool under construction in Anapa. The general goal of this research is to identify the seismic stability of the building structure. An unbalance-type vibration machine was used in the course of the testing procedure. The machine was designed and manufactured at Moscow State University of Civil Engineering. Identification of natural vibrations of building structures and verification of the identity of the computer model and the natural behaviour of the structure were to be completed to assess the required modes of operation of the vibration machine. Identification of full-scale dynamic characteristics was performed through the employment of the impulse method of vibration excitation. Comparative analysis of experimental vibration frequencies and eigenfrequencies identified in the course of calculations based on different mathematical models demonstrates their similarity in terms of local shapes of vibrations, namely, in terms of buckling vibrations of an "annular" beam employed for the purpose of measurements taken in the course of the testing procedure. Frequency values identified in the course of testing and calculations vary from 4.5 to 19.8 Hz. Calibration of the vibration machine represents another objective of the experiment. The experiment has demonstrated that the whole operating range of frequencies (2 to 15Hz) is to be employed in the course of testing procedures described above.
    • ISSN:
      1997-0935
    • Relation:
      http://vestnikmgsu.ru/files/archive/issues/2012/5/ru/16.pdf; https://doaj.org/toc/1997-0935; https://doaj.org/article/6d8ef1da75fa45bd93525d90cfa415d8
    • الرقم المعرف:
      edsbas.56D364B2