In-house 3D-printed aligners: effect of in vivo ageing on mechanical properties

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Oxford University Press
    • الموضوع:
      2022
    • Collection:
      University of Zurich (UZH): ZORA (Zurich Open Repository and Archive
    • نبذة مختصرة :
      OBJECTIVE To investigate alterations in the mechanical properties of in-house three-dimensional (3D) printed orthodontic aligners after intraoral ageing. MATERIALS AND METHODS Sixteen 3D-printed aligners (TC-85DAC resin, Graphy, Seoul, Korea) were used for the purpose of the study, which were divided into 10 control (not used) aligners and 6 materials retrieved from 4 patients after 1-week service (retrieved group). Samples from the control group were analysed by attenuated total reflectance-Fourier-transform infrared (ATR-FTIR) spectroscopy. Samples from control/retrieved groups were embedded resin and subjected to instrumented indentation testing (IIT) to record force-indentation depth curves, calculating the following (as per ISO 14577-1, 2002 standard): Martens hardness (HM), indentation modulus (EIT), and elastic index (ηIT), and the indentation relaxation index (RIT). Differences between control and retrieved 3D-printed aligners were checked with Mann-Whitney/t-tests at an alpha = 5%. RESULTS ATR-FTIR analysis showed that aligners were made of a vinyl ester-urethane material. The results of the IIT testing were: HM (control: median 91.5 N/mm2, interquartile range [IQR] 88.0-93.0/as-retrieved: median 90.5 N/mm2, IQR 89.0-93.0); EIT (control, mean 2616.3 MPa, standard deviation [SD] 107.0 MPa/retrieved, mean 2673.2 MPa, SD 149.4 MPa); ηIT (control: median 28.6%, IQR 28.2-30.9%/as-retrieved: median 29.0%, IQR 28.7-29.2%); and RIT (control: median 45.5%, IQR 43.0-47.0%/as-retrieved: median 45.1%, IQR 45.0-45.3%). No differences between as-retrieved and control aligners were found for any of the mechanical properties tested (P > 0.05 in all instances). CONCLUSION The mechanical properties of the in-house 3D-printed aligners tested were not affected after 1 week in service period.
    • File Description:
      application/pdf
    • ISSN:
      0141-5387
    • Relation:
      https://www.zora.uzh.ch/id/eprint/225040/1/3D_printed_alligners_Retrived_vs_Control_EJO__002_.pdf; info:pmid/33950232; urn:issn:0141-5387
    • الرقم المعرف:
      10.1093/ejo/cjab022
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.553FA0EC