      Institut des Sciences Chimiques de Rennes (ISCR); Université de Rennes (UR)-Institut National des Sciences Appliquées - Rennes (INSA Rennes); Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Ecole Nationale Supérieure de Chimie de Rennes (ENSCR)-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS); Université Frères Mentouri – Constantine 1 = Constantine 1 – Frères Mentouri University (UMC); Iuliu Haţieganu University of Medicine and Pharmacy of Cluj-Napoca = Universitatea de Medicină şi Farmacie Iuliu Haţieganu din Cluj-Napoca (UMF); Bureau de Recherches Géologiques et Minières (BRGM); Institut de Physique de Rennes (IPR); Université de Rennes (UR)-Centre National de la Recherche Scientifique (CNRS); Systèmes et Applications des Technologies de l'Information et de l'Energie (SATIE); École normale supérieure - Rennes (ENS Rennes)-Conservatoire National des Arts et Métiers CNAM (CNAM)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)-Ecole Normale Supérieure Paris-Saclay (ENS Paris Saclay)-Université Gustave Eiffel-CY Cergy Paris Université (CY); Institut d'Électronique et des Technologies du numéRique (IETR); Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-CentraleSupélec-Centre National de la Recherche Scientifique (CNRS)-Nantes Université - pôle Sciences et technologie; Nantes Université (Nantes Univ)-Nantes Université (Nantes Univ); ANR-18-CE42-0011,EASCVsens,Voltammétrie par échantillonnage de courant sur réseau d'électrodes pour la détection des éléments-traces métalliques dans les eaux(2018)
    • بيانات النشر:
      HAL CCSD
      Elsevier
    • الموضوع:
      2023
    • Collection:
      Université Paris Seine: ComUE (HAL)
    • نبذة مختصرة :
      International audience ; Selective and sensitive cadmium sensors were prepared by functionalizing glassy carbon electrodes (GCE) using the electrochemical reduction of p-benzoic acid diazonium salts according to either a multilayer or a monolayer coating process. Such modified electrodes were then post-functionalized with 1,2-bis-[o-aminophenylthio]ethane (APTE) or its monoprotected derivative leading to specific Cd2+ electrochemical sensors. The step by step preparation of the electrodes as well as the ability of the immobilized receptor to complex Cd2+ was investigated by XPS and Raman spectroscopy. The detection and quantification of cadmium was performed in two steps: the preconcentration of Cd2+ ions by complexation with immobilized APTE and the analysis by Linear Sweep Stripping Voltammetry (LSSV). More importantly, multilayer versus monolayer grafting has a strong influence on the sensor performances. Whereas calibration curves typical of an equilibrium process were obtained for sensors realized with multilayer organic films, sensors with a monolayer organic film led to linear calibration curves, in the same concentration range. Finally, the monolayer sensor gave a lower limit of detection (LOD) and highlighted better selectivity than unmodified electrode.
    • Relation:
      hal-04205041; https://brgm.hal.science/hal-04205041; https://brgm.hal.science/hal-04205041/document; https://brgm.hal.science/hal-04205041/file/Article_HAL.pdf
    • الرقم المعرف:
      10.1016/j.electacta.2023.142962
    • Rights:
      info:eu-repo/semantics/OpenAccess
    • الرقم المعرف:
      edsbas.51CED111