Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Five-year outcomes of the GORE VIABAHN Endoprosthesis for the treatment of complex femoropopliteal lesions from a Japanese postmarket surveillance study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      w. l. gore and associates
    • بيانات النشر:
      SAGE Publications
    • الموضوع:
      2024
    • نبذة مختصرة :
      Introduction: The safety and effectiveness of the GORE VIABAHN Endoprosthesis for treatment of symptomatic patients with peripheral artery disease (PAD) and complex femoropopliteal (FP) lesions was assessed in a real-world Japanese practice setting. Methods: A prospective, multicenter, postmarket surveillance study was conducted from 2016 to 2017 at 64 sites in Japan. Symptomatic patients with PAD and FP lesions ⩾ 10 cm and reference vessel diameters ranging from 4.0 to 7.5 mm were eligible for enrollment. Outcome measures evaluated at 5 years were primary patency (PP), primary-assisted patency (PAP), secondary patency (SP), freedom from target lesion revascularization (fTLR), occurrence of device- or procedure-related serious adverse events (SAEs), and stent fractures. Results: A total of 321 patients were enrolled and were a mean age of 73.9 ± 8.7 years; 77.3% were men and 26.5% had chronic limb-threatening ischemia (CLTI). The mean lesion length was 23.6 ± 6.6 cm and the frequency with TASC II C/D lesions and chronic total occlusions was 86.6% and 70.4%, respectively. The Kaplan–Meier estimated PP, PAP, SP, and fTLR at 5 years was 62.4%, 74.1%, 82.3%, and 75.9%, respectively. The mean ankle–brachial index was 0.92 ± 0.15 and the mean improvement in Rutherford class was 2.3 ± 1.4, which was maintained through 5 years. The rate of cumulative device- or procedure-related SAEs through 5 years was 19.9% with only 9.3% of those occurring after the first year. No stent fractures were observed through 5 years by x-ray evaluation. Conclusion: The 5-year safety and efficacy outcomes of the endoprosthesis were clinically acceptable for treating complex FP lesions in a real-world cohort of Japanese patients with PAD. (ClinicalTrials.gov Identifier: NCT04706273)
    • الرقم المعرف:
      10.1177/1358863x241233528
    • الرقم المعرف:
      10.1177/1358863X241233528
    • Rights:
      https://creativecommons.org/licenses/by-nc/4.0/
    • الرقم المعرف:
      edsbas.5043860B