Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Semi-automatic detection of myocardial trabeculation using cardiovascular magnetic resonance: correlation with histology and reproducibility in a mouse model of non-compaction

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      Centre de résonance magnétique biologique et médicale (CRMBM); Aix Marseille Université (AMU)-Assistance Publique - Hôpitaux de Marseille (APHM)-Centre National de la Recherche Scientifique (CNRS); Laboratoire Electronique, Informatique et Image UMR6306 (Le2i); Université de Bourgogne (UB)-École Nationale Supérieure d'Arts et Métiers (ENSAM)-AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement-Centre National de la Recherche Scientifique (CNRS); Institut de Biologie du Développement de Marseille (IBDM); Aix Marseille Université (AMU)-Collège de France (CdF (institution))-Centre National de la Recherche Scientifique (CNRS); Hôpital de la Timone CHU - APHM (TIMONE); Radiopharmaceutiques biocliniques; Université Joseph Fourier - Grenoble 1 (UJF)-Institut National de la Santé et de la Recherche Médicale (INSERM); Assistance Publique - Hôpitaux de Marseille (APHM); ANR-11-INBS-0006,FLI,France Life Imaging(2011)
    • بيانات النشر:
      CCSD
      BioMed Central
    • الموضوع:
      2018
    • Collection:
      Université de Bourgogne (UB): HAL
    • نبذة مختصرة :
      International audience ; Background: The definition of left ventricular (LV) non-compaction is controversial, and discriminating between normal and excessive LV trabeculation remains challenging. Our goal was to quantify LV trabeculation on cardiovascular magnetic resonance (CMR) images in a genetic mouse model of non-compaction using a dedicated semi-automatic software package and to compare our results to the histology used as a gold standard.MethodsAdult mice with ventricular non-compaction were generated by conditional trabecular deletion of Nkx2–5. Thirteen mice (5 controls, 8 Nkx2–5 mutants) were included in the study. Cine CMR series were acquired in the mid LV short axis plane (resolution 0.086 × 0.086x1mm3) (11.75 T). In a sub set of 6 mice, 5 to 7 cine CMR were acquired in LV short axis to cover the whole LV with a lower resolution (0.172 × 0.172x1mm3). We used semi-automatic software to quantify the compacted mass (Mc), the trabeculated mass (Mt) and the percentage of trabeculation (Mt/Mc) on all cine acquisitions. After CMR all hearts were sliced along the short axis and stained with eosin, and histological LV contouring was performed manually, blinded from the CMR results, and Mt, Mc and Mt/Mc were quantified. Intra and interobserver reproducibility was evaluated by computing the intra class correlation coefficient (ICC).Results: Whole heart acquisition showed no statistical significant difference between trabeculation measured at the basal, midventricular and apical parts of the LV. On the mid-LV cine CMR slice, the median Mt was 0.92 mg (range 0.07–2.56 mg), Mc was 12.24 mg (9.58–17.51 mg), Mt/Mc was 6.74% (0.66–17.33%). There was a strong correlation between CMR and the histology for Mt, Mc and Mt/ Mc with respectively: r2 = 0.94 (p < 0.001), r2 = 0.91 (p < 0.001), r2 = 0.83 (p < 0.001). Intra- and interobserver reproducibility was 0.97 and 0.8 for Mt; 0.98 and 0.97 for Mc; 0.96 and 0.72 for Mt/Mc, respectively and significantly more trabeculation was observed in the Mc Mutant mice than ...
    • الرقم المعرف:
      10.1186/s12968-018-0489-0
    • الدخول الالكتروني :
      https://hal.science/hal-02115412
      https://hal.science/hal-02115412v1/document
      https://hal.science/hal-02115412v1/file/12968_2018_Article_489.pdf
      https://doi.org/10.1186/s12968-018-0489-0
    • Rights:
      info:eu-repo/semantics/OpenAccess
    • الرقم المعرف:
      edsbas.400DAB19