Clinical utility of existing and second-generation interferon-γ release assays for diagnostic evaluation of tuberculosis: an observational cohort study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      National Institute for Health Research
    • بيانات النشر:
      Elsevier
    • الموضوع:
      2018
    • Collection:
      Imperial College London: Spiral
    • الموضوع:
    • نبذة مختصرة :
      BACKGROUND: The clinical utility of interferon-γ release assays (IGRAs) for diagnosis of active tuberculosis is unclear, although they are commonly used in countries with a low incidence of tuberculosis. We aimed to resolve this clinical uncertainty by determining the accuracy and utility of commercially available and second-generation IGRAs in the diagnostic assessment of suspected tuberculosis in a low-incidence setting. METHODS: We did a prospective cohort study of adults with suspected tuberculosis in routine secondary care in England. Patients were tested for Mycobacterium tuberculosis infection at baseline with commercially available (T-SPOT.TB and QuantiFERON-TB Gold In-Tube [QFT-GIT]) and second-generation (incorporating novel M tuberculosis antigens) IGRAs and followed up for 6-12 months to establish definitive diagnoses. Sensitivity, specificity, positive and negative likelihood ratios, and predictive values of the tests were determined. FINDINGS: Of the 1060 adults enrolled in the study, 845 were eligible and 363 were diagnosed with tuberculosis. Sensitivity of T-SPOT.TB for all tuberculosis diagnosis was 81·4% (95% CI 76·6-85·3), which was higher than QFT-GIT (67·3% [62·0-72·1]). Second-generation IGRAs had a sensitivity of 94·0% (90·0-96·4) for culture-confirmed tuberculosis and 89·2% (85·2-92·2) when including highly probable tuberculosis, giving a negative likelihood ratio for all tuberculosis cases of 0·13 (95% CI 0·10-0·19). Specificity ranged from 86·2% (95% CI 82·3-89·4) for T-SPOT.TB to 80·0% (75·6-83·8) for second-generation IGRAs. INTERPRETATION: Commercially available IGRAs do not have sufficient accuracy for diagnostic evaluation of suspected tuberculosis. Second-generation tests, however, might have sufficiently high sensitivity, low negative likelihood ratio, and correspondingly high negative predictive value in low-incidence settings to facilitate prompt rule-out of tuberculosis. FUNDING: National Institute for Health Research.
    • ISSN:
      1473-3099
    • Relation:
      Lancet Infectious Diseases; http://hdl.handle.net/10044/1/66146; RDB21 79560; NF-SI-0508-10179; 08/106/02; NF-SI-0513-10155; RP-2016-07-012
    • الرقم المعرف:
      10.1016/S1473-3099(18)30613-3
    • Rights:
      © 2019 Elsevier Ltd. All rights reserved. This manuscript is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International Licence http://creativecommons.org/licenses/by-nc-nd/4.0/
    • الرقم المعرف:
      edsbas.3F76E60C