Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Real Time QRS Detection Based on M-ary Likelihood Ratio Test on the DFT Coefficients

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Public Library of Science (PLOS)
    • الموضوع:
      2014
    • Collection:
      DIGIBUG: Repositorio Institucional de la Universidad de Granada
    • نبذة مختصرة :
      This paper shows an adaptive statistical test for QRS detection of electrocardiography (ECG) signals. The method is based on a M-ary generalized likelihood ratio test (LRT) defined over a multiple observation window in the Fourier domain. The motivations for proposing another detection algorithm based on maximum a posteriori (MAP) estimation are found in the high complexity of the signal model proposed in previous approaches which i) makes them computationally unfeasible or not intended for real time applications such as intensive care monitoring and (ii) in which the parameter selection conditions the overall performance. In this sense, we propose an alternative model based on the independent Gaussian properties of the Discrete Fourier Transform (DFT) coefficients, which allows to define a simplified MAP probability function. In addition, the proposed approach defines an adaptive MAP statistical test in which a global hypothesis is defined on particular hypotheses of the multiple observation window. In this sense, the observation interval is modeled as a discontinuous transmission discrete-time stochastic process avoiding the inclusion of parameters that constraint the morphology of the QRS complexes. ; This work has received research funding from the Spanish government (www.micinn.es) under project TEC2012 34306 (DiagnoSIS, Diagnosis by means of Statistical Intelligent Systems, 70K€) and projects P09-TIC-4530 (300K€) and P11-TIC-7103 (156K€) from the Andalusian government (http://www.juntadeandalucia.es/organismos/economiainnovacioncienciayempleo.html).
    • File Description:
      application/pdf
    • ISSN:
      1932-6203
    • Relation:
      Górriz, J.M.; et al. Real Time QRS Detection Based on M-ary Likelihood Ratio Test on the DFT Coefficients. Plos One, 9(10): e110629 (2014). [http://hdl.handle.net/10481/33852]; http://hdl.handle.net/10481/33852
    • الرقم المعرف:
      10.1371/journal.pone.0110629
    • الدخول الالكتروني :
      http://hdl.handle.net/10481/33852
      https://doi.org/10.1371/journal.pone.0110629
    • Rights:
      Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License ; http://creativecommons.org/licenses/by-nc-nd/3.0/ ; info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.35BCD6CB