Mycobacterium detection method combining filtration, immunomagnetic separation, and electrochemical readout in a portable biosensing device

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2024
    • Collection:
      Universitat Autònoma de Barcelona: Dipòsit Digital de Documents de la UAB
    • نبذة مختصرة :
      Altres ajuts: acords transformatius de la UAB ; This study addresses a straightforward and highly sensitive approach for detecting Mycobacterium fortuitum. The method involves a combination of filtration and direct immunomagnetic separation to isolate the bacteria retained on filters for further electrochemical magneto immunosensing in a handheld device. Unlike conventional methods involving pre-enrichment by culturing, this approach employs a simplified preconcentration technique, which includes filtration of large water samples, up to 100 mL, followed by a one-step process of immunomagnetic separation and labeling. After a 60-min, during which the filter with the retained bacteria and all the reagents (including modified magnetic particles and enzymatic conjugates) are incubated, the resulting product is directly drop into a cartridge, capable of performing magnetic actuation and washing. The electrochemical readout is carried out on a portable battery-operated device within 30 seconds. Remarkably, the immunosensor demonstrates an outstanding limit of detection of 5 CFU mL−1 in hemodialysis water processing 100 mL of sample. This achievement is remarkable considering the short and simplified analytical procedure, compared to the traditional isolation and culturing of mycobacteria, which typically takes 2 weeks.
    • File Description:
      application/pdf
    • ISBN:
      978-2-01-708074-9
      2-01-708074-8
    • ISSN:
      18733077
    • Relation:
      Agencia Estatal de Investigación PID2019-106625RB-I00; Agencia Estatal de Investigación PID2022-136453OB-I00; Agència de Gestió d'Ajuts Universitaris i de Recerca 2017/SGR-220; Agència de Gestió d'Ajuts Universitaris i de Recerca 2021/SGR-00124; Agència de Gestió d'Ajuts Universitaris i de Recerca 2021/SGR-00092; Agència de Gestió d'Ajuts Universitaris i de Recerca 2021/SGR-1267; Agencia Estatal de Investigación BES-2017-080748; Sensors and actuators. B, Chemical; Vol. 403 (March 2024), art. 135211; https://ddd.uab.cat/record/287860; urn:10.1016/j.snb.2023.135211; urn:oai:ddd.uab.cat:287860; urn:oai:egreta.uab.cat:publications/ffcb0510-24cd-4c43-8077-35ac0e551db2; urn:pure_id:408974413; urn:scopus_id:85181721979; urn:articleid:18733077v403p135211
    • الدخول الالكتروني :
      https://ddd.uab.cat/record/287860
    • Rights:
      open access ; Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. ; https://creativecommons.org/licenses/by/4.0/
    • الرقم المعرف:
      edsbas.355A5CBF