Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Adherence to Lung-Protective Ventilation Principles in Pediatric Acute Respiratory Distress Syndrome:A Pediatric Acute Respiratory Distress Syndrome Incidence and Epidemiology Study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2021
    • Collection:
      University of Groningen research database
    • نبذة مختصرة :
      OBJECTIVES: To describe mechanical ventilation management and factors associated with nonadherence to lung-protective ventilation principles in pediatric acute respiratory distress syndrome. DESIGN: A planned ancillary study to a prospective international observational study. Mechanical ventilation management (every 6 hr measurements) during pediatric acute respiratory distress syndrome days 0-3 was described and compared with Pediatric Acute Lung Injury Consensus Conference tidal volume recommendations (< 7 mL/kg in children with impaired respiratory system compliance, < 9 mL/kg in all other children) and the Acute Respiratory Distress Syndrome Network lower positive end-expiratory pressure/higher FIO2 grid recommendations. SETTING: Seventy-one international PICUs. PATIENTS: Children with pediatric acute respiratory distress syndrome. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Analyses included 422 children. On pediatric acute respiratory distress syndrome day 0, median tidal volume was 7.6 mL/kg (interquartile range, 6.3-8.9 mL/kg) and did not differ by pediatric acute respiratory distress syndrome severity. Plateau pressure was not recorded in 97% of measurements. Using delta pressure (peak inspiratory pressure - positive end-expiratory pressure), median tidal volume increased over quartiles of median delta pressure (p = 0.007). Median delta pressure was greater than or equal to 18 cm H2O for all pediatric acute respiratory distress syndrome severity levels. In severe pediatric acute respiratory distress syndrome, tidal volume was greater than or equal to 7 mL/kg 62% of the time, and positive end-expiratory pressure was lower than recommended by the positive end-expiratory pressure/FIO2 grid 70% of the time. In multivariable analysis, tidal volume nonadherence was more common with severe pediatric acute respiratory distress syndrome, fewer PICU admissions/yr, non-European PICUs, higher delta pressure, corticosteroid use, and pressure control mode. Adherence was associated with underweight ...
    • File Description:
      application/pdf
    • الرقم المعرف:
      10.1097/CCM.0000000000005060
    • الدخول الالكتروني :
      https://hdl.handle.net/11370/34f27262-72ea-4261-9471-bbad51c563fe
      https://research.rug.nl/en/publications/34f27262-72ea-4261-9471-bbad51c563fe
      https://doi.org/10.1097/CCM.0000000000005060
      https://pure.rug.nl/ws/files/179019048/Adherence_to_Lung_Protective_Ventilation.95237.pdf
    • Rights:
      info:eu-repo/semantics/openAccess
    • الرقم المعرف:
      edsbas.2A155B3A