Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Outcomes of cystoid macular edema following Descemet's membrane endothelial keratoplasty in a referral center for keratoplasty in Spain : retrospective study

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • الموضوع:
      2023
    • Collection:
      Universitat Autònoma de Barcelona: Dipòsit Digital de Documents de la UAB
    • نبذة مختصرة :
      The aim of this study was to analyze the outcomes of eyes with visually significant cystoid macular œdema (vs-CMO) after Descemet membrane endothelial keratoplasty (DMEK) in a referral center for keratoplasty in Spain. We conducted a retrospective, single-surgeon case series of eyes that developed post-DMEK vs-CMO performed between January 2011 and December 2020. Data collected included: indication for DMEK; biometric data; ocular comorbidities; past medical history; time to detection of vs-CMO after DMEK (T, weeks); best-corrected visual acuity (BCVA, logMAR) and central retinal thickness (CRT, µm) at diagnosis of vs-CMO, after resolution of CMO, and at last follow-up; and management strategy. Main outcomes analyzed were incidence of vs-CMO, improvement in BCVA and CRT after treatment of vs-CMO. Of 291 consecutive DMEK surgeries, 14 eyes of 13 patients (4.8%) developed vs-CMO. Five patients (38.5%) had history of CMO, and 28.6% of eyes had ophthalmic comorbidities. Median (P25-P75) T was 4 (3-10) weeks. Treatment success was observed in 12/13 eyes (92.3%), two of which required second-line treatment. In successful cases (median time-to-resolution 3.0 (2.0-3.5) months), median BCVA improved from 0.60 (0.40-0.80) logMAR to 0.30 (0.15-0.40) logMAR (p = 0.002) after treatment, and median CRT improved from 582.5 (400.0-655.0) µm to 278.0 (258.0-294.0) µm (p = 0.005). In our study, we found a 4.8% rate of post-DMEK vs-CMO, with most cases occurring in the first 3 months after surgery. Good functional and anatomical outcomes are expected in most eyes, without treatment-related complications or implications in graft outcomes. Additional studies are encouraged to determine a standardized protocol for post-DMEK vs-CMO.
    • File Description:
      application/pdf
    • Relation:
      Scientific reports; Vol. 13 (february 2023); https://ddd.uab.cat/record/281383; urn:10.1038/s41598-023-29127-5; urn:oai:ddd.uab.cat:281383; urn:pmcid:PMC9911599; urn:pmc-uid:9911599; urn:pmid:36759529; urn:oai:pubmedcentral.nih.gov:9911599
    • Rights:
      open access ; Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. ; https://creativecommons.org/licenses/by/4.0/
    • الرقم المعرف:
      edsbas.1BEE90B6