Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Cardiopulmonary Exercise Testing after Surgical Repair of Tetralogy of Fallot—Does Modality Matter?

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      MDPI AG
    • الموضوع:
      2024
    • Collection:
      Directory of Open Access Journals: DOAJ Articles
    • نبذة مختصرة :
      Background: Despite a successful repair of tetralogy of Fallot (rToF) in childhood, residual lesions are common and can contribute to impaired exercise capacity. Although both cycle ergometer and treadmill protocols are often used interchangeably these approaches have not been directly compared. In this study we examined cardiopulmonary exercise test (CPET) measurements in rToF. Methods: Inclusion criteria were clinically stable rToF patients able to perform a cardiac magnetic resonance imaging (CMR) and two CPET studies, one on the treadmill (incremental Bruce protocol) and one on the cycle ergometer (ramped protocol), within 12 months. Demographic, surgical and clinical data; functional class; QRS duration; CMR measures; CPET data and international physical activity questionnaire (IPAQ) scores of patients were collected. Results: Fifty-seven patients were enrolled (53% male, 20.5 ± 7.8 years at CPET). CMR measurements included a right ventricle (RV) end-diastolic volume index of 119 ± 22 mL/m 2 , a RV ejection fraction (EF) of 55 ± 6% and a left ventricular (LV) EF of 56 ± 5%. Peak oxygen consumption (VO 2 )/Kg (25.5 ± 5.5 vs. 31.7 ± 6.9; p < 0.0001), VO 2 at anaerobic threshold (AT) (15.3 ± 3.9 vs. 22.0 ± 4.5; p < 0.0001), peak O 2 pulse (10.6 ± 3.0 vs. 12.1± 3.4; p = 0.0061) and oxygen uptake efficiency slope (OUES) (1932.2 ± 623.6 vs. 2292.0 ± 639.4; p < 0.001) were significantly lower on the cycle ergometer compared with the treadmill, differently from ventilatory efficiency (VE/VCO 2 ) max which was significantly higher on the cycle ergometer (32.2 ± 4.5 vs. 30.4 ± 5.4; p < 0.001). Only the VE/VCO 2 slope at the respiratory compensation point (RCP) was similar between the two methodologies ( p = 0.150). Conclusions: The majority of CPET measurements differed according to the modality of testing, with the exception being the VE/VCO 2 slope at RCP. Our data suggest that CPET parameters should be interpreted according to test type; however, these findings should be validated in larger populations ...
    • ISSN:
      2077-0383
    • Relation:
      https://www.mdpi.com/2077-0383/13/5/1192; https://doaj.org/toc/2077-0383; https://doaj.org/article/60769e2c1ccb4a9c9937492ca86f1eab
    • الرقم المعرف:
      10.3390/jcm13051192
    • الدخول الالكتروني :
      https://doi.org/10.3390/jcm13051192
      https://doaj.org/article/60769e2c1ccb4a9c9937492ca86f1eab
    • الرقم المعرف:
      edsbas.10E8305