Screening for iron deficiency in surgical patients based on noninvasive zinc protoporphyrin measurements

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • Contributors:
      University of Zurich; Meybohm, Patrick
    • بيانات النشر:
      Wiley, 2019.
    • الموضوع:
      2019
    • نبذة مختصرة :
      BACKGROUND: Approximately every third surgical patient is anemic. The most common form, iron deficiency anemia, results from persisting iron-deficient erythropoiesis (IDE). Zinc protoporphyrin (ZnPP) is a promising parameter for diagnosing IDE, hitherto requiring blood drawing and laboratory workup. STUDY DESIGN AND METHODS: Noninvasive ZnPP (ZnPP-NI) measurements are compared to ZnPP reference determination of the ZnPP/heme ratio by high-performance liquid chromatography (ZnPP-HPLC) and the analytical performance in detecting IDE is evaluated against traditional iron status parameters (ferritin, transferrin saturation [TSAT], soluble transferrin receptor-ferritin index [sTfR-F], soluble transferrin receptor [sTfR]), likewise measured in blood. The study was conducted at the University Hospitals of Frankfurt and Zurich. RESULTS: Limits of agreement between ZnPP-NI and ZnPP-HPLC measurements for 584 cardiac and noncardiac surgical patients equaled 19.7 μmol/mol heme (95% confidence interval, 18.0-21.3; acceptance criteria, 23.2 μmol/mol heme; absolute bias, 0 μmol/mol heme). Analytical performance for detecting IDE (inferred from area under the curve receiver operating characteristics) of parameters measured in blood was: ZnPP-HPLC (0.95), sTfR (0.92), sTfR-F (0.89), TSAT (0.87), and ferritin (0.67). Noninvasively measured ZnPP-NI yielded results of 0.90. CONCLUSION: ZnPP-NI appears well suited for an initial IDE screening, informing on the state of erythropoiesis at the point of care without blood drawing and laboratory analysis. Comparison with a multiparameter IDE test revealed that ZnPP-NI values of 40 μmol/mol heme or less allows exclusion of IDE, whereas for 65 μmol/mol heme or greater, IDE is very likely if other causes of increased values are excluded. In these cases (77% of our patients) ZnPP-NI may suffice for a diagnosis, while values in between require analyses of additional iron status parameters.
    • File Description:
      F-llenbach_et_al-2019-Transfusion.pdf - application/pdf
    • ISSN:
      1537-2995
      0041-1132
    • الرقم المعرف:
      10.1111/trf.15577
    • Rights:
      OPEN
    • الرقم المعرف:
      edsair.doi.dedup.....a99052c32996d8ef465becf907bfb126