Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • معلومة اضافية
    • بيانات النشر:
      Public Library of Science (PLoS), 2011.
    • الموضوع:
      2011
    • نبذة مختصرة :
      Background There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. Methodology/Principal Findings In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following ‘scrub typhus infection criteria’ (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the ‘gold standard’ indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96–99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. Conclusions/Significance The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.
      Author Summary There is an urgent need for alternative diagnostic methods for scrub typhus, but evaluation of these is hampered because the current serological gold standard (IFA) is imperfect. In a study from Thailand, 3 of 20 (15%) patients with fever had a positive Orientia tsutsugamushi PCR result despite negative serology. These findings could reflect potential benefits of the PCR assay in detecting rickettsaemia before antibody responses set in and/or a diagnostic advantage in endemic areas with high background levels of antibody in the population. Serology is complicated by the heterogeneity of strains present in Southeast Asia, but high resource costs and training make realtime PCR assays impractical for many areas where scrub typhus is endemic. This is where the new LAMP methodology has potential: it is inexpensive, simple to perform and requires only a waterbath or simple heating block instead of a thermocycler. In the context of a prospective fever study in a scrub typhus-endemic area in Thailand, the results support the validity of LAMP methodology for the diagnosis of scrub typhus, highlight the difficulties in comparing antibody- with DNA-based methods and also contribute towards understanding the dynamics of bacteraemia in this under recognised and under studied disease.
    • ISSN:
      1935-2735
      1935-2727
    • Rights:
      OPEN
    • الرقم المعرف:
      edsair.doi.dedup.....a491b4029399bbe15ddc75d54691a88f